A novel dynamic simulation model for the building envelope energy performance analysis is presented in this paper. This tool helps the investigation of many new building technologies to increase the system 36 energy efficiency and it can be carried out for scientific research purposes. In addition to the yearly heat- 37 ing and cooling load and energy demand, the obtained output is the dynamic temperature profile of 38 indoor air and surfaces and the dynamic profile of the thermal fluxes through the building elements. The presented simulation model is also validated through the BESTEST standard procedure. Several new case studies are developed for assessing, through the presented code, the energy performance of three different building envelopes with several different weather conditions. In particular, dwelling and commercial buildings are analysed. Light and heavyweight envelopes as well as different glazed surfaces areas have been used for every case study. With the achieved results interesting design and operating guidelines can be obtained. Such data have been also compared vs. those calculated by TRNSYS and EnergyPlus. The detected deviation of the obtained results vs. those of such standard tools are almost always lower than 10%.

Building energy performance analysis by an in-house developed dynamic simulation code: an investigation for different case studies / Buonomano, Annamaria; Palombo, Adolfo. - In: APPLIED ENERGY. - ISSN 0306-2619. - 113:(2014), pp. 788-807. [10.1016/j.apenergy.2013.08.004]

Building energy performance analysis by an in-house developed dynamic simulation code: an investigation for different case studies

BUONOMANO, ANNAMARIA;PALOMBO, ADOLFO
2014

Abstract

A novel dynamic simulation model for the building envelope energy performance analysis is presented in this paper. This tool helps the investigation of many new building technologies to increase the system 36 energy efficiency and it can be carried out for scientific research purposes. In addition to the yearly heat- 37 ing and cooling load and energy demand, the obtained output is the dynamic temperature profile of 38 indoor air and surfaces and the dynamic profile of the thermal fluxes through the building elements. The presented simulation model is also validated through the BESTEST standard procedure. Several new case studies are developed for assessing, through the presented code, the energy performance of three different building envelopes with several different weather conditions. In particular, dwelling and commercial buildings are analysed. Light and heavyweight envelopes as well as different glazed surfaces areas have been used for every case study. With the achieved results interesting design and operating guidelines can be obtained. Such data have been also compared vs. those calculated by TRNSYS and EnergyPlus. The detected deviation of the obtained results vs. those of such standard tools are almost always lower than 10%.
2014
Building energy performance analysis by an in-house developed dynamic simulation code: an investigation for different case studies / Buonomano, Annamaria; Palombo, Adolfo. - In: APPLIED ENERGY. - ISSN 0306-2619. - 113:(2014), pp. 788-807. [10.1016/j.apenergy.2013.08.004]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/560738
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 89
  • ???jsp.display-item.citation.isi??? 72
social impact