Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
The main results of the R&D program of the FAZIA collaboration are described. The objective was to improve particle identi???cation capabilities from
solid-state telescopes made of Silicon detectors and CsI(Tl) scintillators in
view of a new large acceptance apparatus to be used for heavy-ion physics.
Important progresses have been made on silicon detectors thanks to a careful
control of the material,of its doping uniformity and of the crystal orientation.
Moreover,the use of appropriate fast digital electronics allowed to extract maximum information via Pulse Shape Analysis and to propose new con???gurations
of CsI(Tl) readout. Some of the recent results of the telescopes are discussed
here,together with some perspective and preliminary data on the physics program at intermediate bombarding energies.
The Fazia initiative: more powerful detectors for a more detailed investigation on the origin and the decay of charged fragments / G., C., S., B., G., P., S., C., N., L.N., M., B., B., B., R., B., P., E., M., M., A., O., G., P., M. F., R., Stefanini, A.A., E., S., G., B., R., B., E., B., M., B., A., C., et al.. - CERN-Proceedings-2012-002:(2012), pp. 407-414. (13th INTERNATIONAL CONFERENCE ON NUCLEAR REACTION MECHANISMS Varenna 11-15 June 2012).
The Fazia initiative: more powerful detectors for a more detailed investigation on the origin and the decay of charged fragments
G. Casini;S. Barlini;G. Pasquali;S. Carboni;N. Le Neindre;M. Bini;B. Borderie;R. Bougault;P. Edelbruck;M. Merciai;A. Olmi;G. Poggi;M. F. Rivet;A.A. Stefanini;E. Scarlini;G. Baiocco;R. Berjillos;E. Bonnet;M. Bruno;A. Chbihi;J. A. Dueñas;F. Gramegna;A. Kordyasz;T. Kozik;L. Kravchuk;O. Lopez;T. Marchi;L. Morelli;M. Parlog;S. Piantelli;ROSATO, ELIO;E. Vient;VIGILANTE, MARIANO
2012
Abstract
The main results of the R&D program of the FAZIA collaboration are described. The objective was to improve particle identi???cation capabilities from
solid-state telescopes made of Silicon detectors and CsI(Tl) scintillators in
view of a new large acceptance apparatus to be used for heavy-ion physics.
Important progresses have been made on silicon detectors thanks to a careful
control of the material,of its doping uniformity and of the crystal orientation.
Moreover,the use of appropriate fast digital electronics allowed to extract maximum information via Pulse Shape Analysis and to propose new con???gurations
of CsI(Tl) readout. Some of the recent results of the telescopes are discussed
here,together with some perspective and preliminary data on the physics program at intermediate bombarding energies.
The Fazia initiative: more powerful detectors for a more detailed investigation on the origin and the decay of charged fragments / G., C., S., B., G., P., S., C., N., L.N., M., B., B., B., R., B., P., E., M., M., A., O., G., P., M. F., R., Stefanini, A.A., E., S., G., B., R., B., E., B., M., B., A., C., et al.. - CERN-Proceedings-2012-002:(2012), pp. 407-414. (13th INTERNATIONAL CONFERENCE ON NUCLEAR REACTION MECHANISMS Varenna 11-15 June 2012).
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/535285
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.