Abstract: Endovenous laser treatment for great saphenous vein appears to be an useful alternative to conventional surgery in treatment of advanced varicose veins, in ambulatory regimen too. A recurring problem in laser applications is estimating the thermal response of target tissues to laser irradiation. This typically involves using an optical model to determine the distribution of absorbed laser energy and then using a thermal model to establish the temperature during and after laser irradiation. In the present work we have calculated the power irradiation of the walls of vessel, hypothesising a diameter of the vein cm 0.8-1.5, a length cm 70-90 and haematic flow equal zero. We used Lambert-Beer law, assuming a cylindrical symmetry in the incoming intensity irradiation (I-o), as in the case in the TEM00 mode. Omitting details we calculated a power irradiation, depending on the vein diameter, of 10-20 watt using diode laser 980 nm. This study offers high importance data in order to foresee the effective transfer of thermal damage to the vein wall through absorption of laser energy.

Thermal response of target tissues to laser irradiation. An optical and thermal model applied to vein wall / Quarto, Gennaro; C., Borriello; Benassai, Giacomo; G., Nunziata; M., Pastore; G., ppe Quarto; Quarto, Ernesto. - STAMPA. - (2005), pp. 41-44. (Intervento presentato al convegno 5th World Congress of the International-Union-of-Phlebology tenutosi a Rio de Janeiro, BRAZIL nel 2005).

Thermal response of target tissues to laser irradiation. An optical and thermal model applied to vein wall

QUARTO, GENNARO;BENASSAI, GIACOMO;QUARTO, ERNESTO
2005

Abstract

Abstract: Endovenous laser treatment for great saphenous vein appears to be an useful alternative to conventional surgery in treatment of advanced varicose veins, in ambulatory regimen too. A recurring problem in laser applications is estimating the thermal response of target tissues to laser irradiation. This typically involves using an optical model to determine the distribution of absorbed laser energy and then using a thermal model to establish the temperature during and after laser irradiation. In the present work we have calculated the power irradiation of the walls of vessel, hypothesising a diameter of the vein cm 0.8-1.5, a length cm 70-90 and haematic flow equal zero. We used Lambert-Beer law, assuming a cylindrical symmetry in the incoming intensity irradiation (I-o), as in the case in the TEM00 mode. Omitting details we calculated a power irradiation, depending on the vein diameter, of 10-20 watt using diode laser 980 nm. This study offers high importance data in order to foresee the effective transfer of thermal damage to the vein wall through absorption of laser energy.
2005
8875871825
Thermal response of target tissues to laser irradiation. An optical and thermal model applied to vein wall / Quarto, Gennaro; C., Borriello; Benassai, Giacomo; G., Nunziata; M., Pastore; G., ppe Quarto; Quarto, Ernesto. - STAMPA. - (2005), pp. 41-44. (Intervento presentato al convegno 5th World Congress of the International-Union-of-Phlebology tenutosi a Rio de Janeiro, BRAZIL nel 2005).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/510341
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact