A new type of plasma lens using a << wall-stabilized >> discharge has been investigated concerning its potential to fine-focus heavy-ion beams. The lens was tested in several runs at the GSI linear accelerator UNILAC with a beam energy of 2.2 GeV and a magnetic rigidity of 1.6 Tm. A remarkably high accuracy and reproducibility of the focusing was found. With a peak current of 22 kA a beam of 1 cm initial diameter was focused down to a spot diameter of below 300 mu m at a distance of 90 mm behind the lens, in agreement with analytical calculations and Monte Carlo simulations of the focusing process. The focal spot size was mainly limited by the beam emittance and no lens-related aberrations could be detected. Plasma lenses are under consideration for use at the SIS/ESR facility of GSI to produce small beam spots on targets in order to achieve high energy density in matter. A design for a plasma lens focusing the beam from the SIS-synchrotron with a typical rigidity of 6Tm is proposed.

The plasma lens solution for heavy-ion beam focusing / A., Tauschwitz; E., Boggasch; D. H. H., Hoffmann; DE MAGISTRIS, Massimiliano; U., Neuner; M., Stetter; R., Tkotz; T., Wagner; W., Seelig; H., Wetzler. - In: NUOVO CIMENTO DELLA SOCIETÀ ITALIANA DI FISICA. A, NUCLEI, PARTICLES AND FIELDS. - ISSN 1124-1861. - 106:11(1993), pp. 1733-1737. [10.1007/BF02821274]

The plasma lens solution for heavy-ion beam focusing

DE MAGISTRIS, MASSIMILIANO;
1993

Abstract

A new type of plasma lens using a << wall-stabilized >> discharge has been investigated concerning its potential to fine-focus heavy-ion beams. The lens was tested in several runs at the GSI linear accelerator UNILAC with a beam energy of 2.2 GeV and a magnetic rigidity of 1.6 Tm. A remarkably high accuracy and reproducibility of the focusing was found. With a peak current of 22 kA a beam of 1 cm initial diameter was focused down to a spot diameter of below 300 mu m at a distance of 90 mm behind the lens, in agreement with analytical calculations and Monte Carlo simulations of the focusing process. The focal spot size was mainly limited by the beam emittance and no lens-related aberrations could be detected. Plasma lenses are under consideration for use at the SIS/ESR facility of GSI to produce small beam spots on targets in order to achieve high energy density in matter. A design for a plasma lens focusing the beam from the SIS-synchrotron with a typical rigidity of 6Tm is proposed.
1993
The plasma lens solution for heavy-ion beam focusing / A., Tauschwitz; E., Boggasch; D. H. H., Hoffmann; DE MAGISTRIS, Massimiliano; U., Neuner; M., Stetter; R., Tkotz; T., Wagner; W., Seelig; H., Wetzler. - In: NUOVO CIMENTO DELLA SOCIETÀ ITALIANA DI FISICA. A, NUCLEI, PARTICLES AND FIELDS. - ISSN 1124-1861. - 106:11(1993), pp. 1733-1737. [10.1007/BF02821274]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/491443
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 9
social impact