The problem of HCFC22 phase-out in refrigeration plants is analysed, A comparison is performed between R22 and R407C, The latter seems a promising drop-in substitute. Indeed, its use in existing plants would only require discharge of mineral oil and refilling with a compatible polyolester oil. The experimental tests are performed in a plant consisting in a water-cooled vapor-compression circuit employed for cooling a water-glycol mixture in a closed-loop system. Both the thermodynamic properties and general performance of R407C are comparable with those of R22. The COP, however, is 5-17% lower, As a consequence, in order to provide the same refrigerating load, a plant working with R407C requires higher electric-power consumption. The operational behaviour of R407C is increasingly better with increasing condensation and evaporation temperature. Therefore, R407C is a good R22 substitute in all applications requiring high evaporation temperatures, such as air-conditioning plants.

R407C as an alternative to R22 in vapour compression plant: An experimental study / Greco, Adriana; Mastrullo, RITA MARIA ANTONIA; Palombo, Adolfo. - In: INTERNATIONAL JOURNAL OF ENERGY RESEARCH. - ISSN 0363-907X. - STAMPA. - 21:12(1997), pp. 1087-1098. [10.1002/(SICI)1099-114X(19971010)21:12<1087::AID-ER330>3.0.CO;2-Y]

R407C as an alternative to R22 in vapour compression plant: An experimental study

GRECO, ADRIANA;MASTRULLO, RITA MARIA ANTONIA;PALOMBO, ADOLFO
1997

Abstract

The problem of HCFC22 phase-out in refrigeration plants is analysed, A comparison is performed between R22 and R407C, The latter seems a promising drop-in substitute. Indeed, its use in existing plants would only require discharge of mineral oil and refilling with a compatible polyolester oil. The experimental tests are performed in a plant consisting in a water-cooled vapor-compression circuit employed for cooling a water-glycol mixture in a closed-loop system. Both the thermodynamic properties and general performance of R407C are comparable with those of R22. The COP, however, is 5-17% lower, As a consequence, in order to provide the same refrigerating load, a plant working with R407C requires higher electric-power consumption. The operational behaviour of R407C is increasingly better with increasing condensation and evaporation temperature. Therefore, R407C is a good R22 substitute in all applications requiring high evaporation temperatures, such as air-conditioning plants.
1997
R407C as an alternative to R22 in vapour compression plant: An experimental study / Greco, Adriana; Mastrullo, RITA MARIA ANTONIA; Palombo, Adolfo. - In: INTERNATIONAL JOURNAL OF ENERGY RESEARCH. - ISSN 0363-907X. - STAMPA. - 21:12(1997), pp. 1087-1098. [10.1002/(SICI)1099-114X(19971010)21:12<1087::AID-ER330>3.0.CO;2-Y]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/490820
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 31
social impact