Steep-front, short-duration voltage pulses occur in power systems as a consequence of lightning, switching of the increasingly used gas-insulated switchgears or by electromagnetic pulses of very high amplitude. Such overvoltages characterised by very fast rise time may produce irreversible damages to the insulation of the different apparatuses of an electric power line. Test results will be presented in this paper concerning the behaviour of cap and pin-glass insulators subjected to steep-front overvoltages. In particular the effect of the glass composition on the insulator performance will be analysed for both normal and anti-fog configurations. Moreover; the dependence of the test results on the polarity of the applied voltage and the electrodes arrangement will also be discussed.

Performances of high-voltage glass insulators subjected to fast transient overvoltages / N., Femia; Lupo', Giovanni; Petrarca, Carlo; V., Tucci; M., Vitelli. - In: EUROPEAN TRANSACTIONS ON ELECTRICAL POWER. - ISSN 1430-144X. - STAMPA. - 6:(1996), pp. 119-124.

Performances of high-voltage glass insulators subjected to fast transient overvoltages

LUPO', GIOVANNI;PETRARCA, CARLO;
1996

Abstract

Steep-front, short-duration voltage pulses occur in power systems as a consequence of lightning, switching of the increasingly used gas-insulated switchgears or by electromagnetic pulses of very high amplitude. Such overvoltages characterised by very fast rise time may produce irreversible damages to the insulation of the different apparatuses of an electric power line. Test results will be presented in this paper concerning the behaviour of cap and pin-glass insulators subjected to steep-front overvoltages. In particular the effect of the glass composition on the insulator performance will be analysed for both normal and anti-fog configurations. Moreover; the dependence of the test results on the polarity of the applied voltage and the electrodes arrangement will also be discussed.
1996
Performances of high-voltage glass insulators subjected to fast transient overvoltages / N., Femia; Lupo', Giovanni; Petrarca, Carlo; V., Tucci; M., Vitelli. - In: EUROPEAN TRANSACTIONS ON ELECTRICAL POWER. - ISSN 1430-144X. - STAMPA. - 6:(1996), pp. 119-124.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/474068
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact