The aim of this study was to delineate the Doppler echocardiographic characteristics of normal and dysfunctioning Carpentier-Edwards bioprostheses. Echocardiographic and Doppler studies were performed on 61 mitral and 41 aortic valves; by means of on clinical evaluation, 15 mitral and 12 aortic valves were considered to be abnormally functioning. The maximum velocity (Vmax) of diastolic left ventricular inflow, pressure half-time and valve orifice area were assessed for prostheses in mitral position, while the maximum velocity (Vmax) of transaortic flow was calculated for prostheses in aortic position. Moreover, the quantitative assessment of mitral and/or aortic regurgitation was performed using the mapping technique with pulsed Doppler wave mode. Normally functioning mitral prostheses were characterized by Vmax less than 2.20 m/s and pressure half-time less than 164 ms; furthermore, mean values of Vmax and pressure half-time were significantly lower in normal than in dysfunctioning prostheses (1.70 +/- 0.33 vs 2.09 +/- 0.52 m/s; p less than 0.01 and 96.14 +/- 29.76 vs 147.87 +/- 57.41 ms; p less than 0.01 respectively). All dysfunctioning mitral valves were characterized by regurgitation graded as severe in 8 cases and moderate in 7 but only 40 and 20% of these presented respectively Vmax and pressure half-time values which were higher than those of normally functioning valves (2.20 m/s and 164 ms respectively); no pure stenosis was found. In the aortic position, normally functioning prostheses were characterized by Vmax less than 3.10 m/s. Furthermore, mean Vmax values were lower in normal than in dysfunctioning prostheses (2.55 +/- 0.53 vs 3.18 +/- 0.80; p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

A Doppler echocardiographic study of normal and dysfunctioning Carpentier-Edwards bioprostheses [Studio eco-Doppler delle bioprotesi di Carpentier-Edwards normo e malfunzionanti.] / Bonaduce, Domenico; Breglio, R; Conforti, G; Montemurro, M. V.; Petretta, Mario; Covino, E; Morgano, G; Bianchi, V.. - In: GIORNALE ITALIANO DI CARDIOLOGIA. - ISSN 0046-5968. - STAMPA. - 20:(1990), pp. 50-57.

A Doppler echocardiographic study of normal and dysfunctioning Carpentier-Edwards bioprostheses [Studio eco-Doppler delle bioprotesi di Carpentier-Edwards normo e malfunzionanti.]

BONADUCE, DOMENICO;PETRETTA, MARIO;
1990

Abstract

The aim of this study was to delineate the Doppler echocardiographic characteristics of normal and dysfunctioning Carpentier-Edwards bioprostheses. Echocardiographic and Doppler studies were performed on 61 mitral and 41 aortic valves; by means of on clinical evaluation, 15 mitral and 12 aortic valves were considered to be abnormally functioning. The maximum velocity (Vmax) of diastolic left ventricular inflow, pressure half-time and valve orifice area were assessed for prostheses in mitral position, while the maximum velocity (Vmax) of transaortic flow was calculated for prostheses in aortic position. Moreover, the quantitative assessment of mitral and/or aortic regurgitation was performed using the mapping technique with pulsed Doppler wave mode. Normally functioning mitral prostheses were characterized by Vmax less than 2.20 m/s and pressure half-time less than 164 ms; furthermore, mean values of Vmax and pressure half-time were significantly lower in normal than in dysfunctioning prostheses (1.70 +/- 0.33 vs 2.09 +/- 0.52 m/s; p less than 0.01 and 96.14 +/- 29.76 vs 147.87 +/- 57.41 ms; p less than 0.01 respectively). All dysfunctioning mitral valves were characterized by regurgitation graded as severe in 8 cases and moderate in 7 but only 40 and 20% of these presented respectively Vmax and pressure half-time values which were higher than those of normally functioning valves (2.20 m/s and 164 ms respectively); no pure stenosis was found. In the aortic position, normally functioning prostheses were characterized by Vmax less than 3.10 m/s. Furthermore, mean Vmax values were lower in normal than in dysfunctioning prostheses (2.55 +/- 0.53 vs 3.18 +/- 0.80; p less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
1990
A Doppler echocardiographic study of normal and dysfunctioning Carpentier-Edwards bioprostheses [Studio eco-Doppler delle bioprotesi di Carpentier-Edwards normo e malfunzionanti.] / Bonaduce, Domenico; Breglio, R; Conforti, G; Montemurro, M. V.; Petretta, Mario; Covino, E; Morgano, G; Bianchi, V.. - In: GIORNALE ITALIANO DI CARDIOLOGIA. - ISSN 0046-5968. - STAMPA. - 20:(1990), pp. 50-57.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/463866
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact