We investigated Legionella and Pseudomonas contamination of hot water in a cross-sectional multicentric survey in Italy. Chemical parameters (hardness, free chlorine, and trace elements) were determined. Legionella spp. were detected in 33 (22.6%) and Pseudomonas spp. in 56 (38.4%) of 146 samples. Some factors associated with Legionella contamination were heater type, tank distance and capacity, water plant age, and mineral content. Pseudomonas presence was influenced by water source, hardness, free chlorine, and temperature. Legionella contamination was associated with a centralized heater, distance from the heater point >10 m, and a water plant >10 years old. Furthermore, zinc levels of <100 microg/L and copper levels of >50 microg/L appeared to be protective against Legionella colonization [corrected]. Legionella species and serogroups were differently distributed according to heater type, water temperature, and free chlorine, suggesting that Legionella strains may have a different sensibility and resistance to environmental factors and different ecologic niches.

Legionella infection risk from domestic hot water / Triassi, Maria; Borella, P; Montagna, Mt; ROMANO SPICA, V; Stampi, S; Stancanelli, G; Neglia, R; Marchesi, I; Fantuzzi, G; Tato, D; Napoli, C; Quaranta, G; Laurenti, P; Leoni, E; DE LUCA, G; Ossi, C; Moro, M; RIBERA D'ALCALA, G.. - In: EMERGING INFECTIOUS DISEASES. - ISSN 1080-6040. - ELETTRONICO. - 10:3(2004), pp. 457-464. [10.3201/eid1003.020707]

Legionella infection risk from domestic hot water.

TRIASSI, MARIA;
2004

Abstract

We investigated Legionella and Pseudomonas contamination of hot water in a cross-sectional multicentric survey in Italy. Chemical parameters (hardness, free chlorine, and trace elements) were determined. Legionella spp. were detected in 33 (22.6%) and Pseudomonas spp. in 56 (38.4%) of 146 samples. Some factors associated with Legionella contamination were heater type, tank distance and capacity, water plant age, and mineral content. Pseudomonas presence was influenced by water source, hardness, free chlorine, and temperature. Legionella contamination was associated with a centralized heater, distance from the heater point >10 m, and a water plant >10 years old. Furthermore, zinc levels of <100 microg/L and copper levels of >50 microg/L appeared to be protective against Legionella colonization [corrected]. Legionella species and serogroups were differently distributed according to heater type, water temperature, and free chlorine, suggesting that Legionella strains may have a different sensibility and resistance to environmental factors and different ecologic niches.
2004
Legionella infection risk from domestic hot water / Triassi, Maria; Borella, P; Montagna, Mt; ROMANO SPICA, V; Stampi, S; Stancanelli, G; Neglia, R; Marchesi, I; Fantuzzi, G; Tato, D; Napoli, C; Quaranta, G; Laurenti, P; Leoni, E; DE LUCA, G; Ossi, C; Moro, M; RIBERA D'ALCALA, G.. - In: EMERGING INFECTIOUS DISEASES. - ISSN 1080-6040. - ELETTRONICO. - 10:3(2004), pp. 457-464. [10.3201/eid1003.020707]
File in questo prodotto:
File Dimensione Formato  
Legionella infection 2004.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Documento in Post-print
Licenza: Dominio pubblico
Dimensione 1.86 MB
Formato Adobe PDF
1.86 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/461130
Citazioni
  • ???jsp.display-item.citation.pmc??? 37
  • Scopus 165
  • ???jsp.display-item.citation.isi??? 183
social impact