We present an autoradiography tool to be used mainly for genetic studies. It performs a quantitative analysis of radioactivity and can follow a dynamic process. We designed several applications, in particular one aimed at detecting hybridization of radio-labeled DNA fragments with known DNA-probes deposited on a micro-array. The technique is based on GaAs pixel array detector and low threshold, large dynamic range and good sensitivity integrated electronics developed for medical applications, suitable to detect markers (gamma or beta) such as 14C, 35S, 33P, 32P, 125I, even at very low activities. A Monte Carlo simulation of β− detection in GaAs is presented here in order to study the spatial resolution characteristics of such a system. For several biological applications, the electronics is required to perform at high temperatures (from 37° to 68°): we present here studies of noise and minimum threshold as a function of the temperature.

GaAs pixel radiation detector as an autoradiography tool for genetic studies / Bertolucci, Ennio; Conti, Maurizio; Mettivier, Giovanni; Russo, Paolo; S. R., Amendolia; M. G., Bisogni; U., Bottigli; A., Ceccopieri; M. A., Ciocci; P., Delogu; M. E., Fantacci; P., Maestro; V. M., Marzulli; E., Pernigotti; N., Romeo; V., Rosso; A., Stefanini; S., Stumbo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 422:1-3(1999), pp. 242-246. [10.1016/S0168-9002(98)01102-4]

GaAs pixel radiation detector as an autoradiography tool for genetic studies

BERTOLUCCI, ENNIO;CONTI, MAURIZIO;METTIVIER, GIOVANNI;RUSSO, PAOLO;
1999

Abstract

We present an autoradiography tool to be used mainly for genetic studies. It performs a quantitative analysis of radioactivity and can follow a dynamic process. We designed several applications, in particular one aimed at detecting hybridization of radio-labeled DNA fragments with known DNA-probes deposited on a micro-array. The technique is based on GaAs pixel array detector and low threshold, large dynamic range and good sensitivity integrated electronics developed for medical applications, suitable to detect markers (gamma or beta) such as 14C, 35S, 33P, 32P, 125I, even at very low activities. A Monte Carlo simulation of β− detection in GaAs is presented here in order to study the spatial resolution characteristics of such a system. For several biological applications, the electronics is required to perform at high temperatures (from 37° to 68°): we present here studies of noise and minimum threshold as a function of the temperature.
1999
GaAs pixel radiation detector as an autoradiography tool for genetic studies / Bertolucci, Ennio; Conti, Maurizio; Mettivier, Giovanni; Russo, Paolo; S. R., Amendolia; M. G., Bisogni; U., Bottigli; A., Ceccopieri; M. A., Ciocci; P., Delogu; M. E., Fantacci; P., Maestro; V. M., Marzulli; E., Pernigotti; N., Romeo; V., Rosso; A., Stefanini; S., Stumbo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 422:1-3(1999), pp. 242-246. [10.1016/S0168-9002(98)01102-4]
File in questo prodotto:
File Dimensione Formato  
gaas 1999.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 116.27 kB
Formato Adobe PDF
116.27 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/460359
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact