Thirteen isothermal ternary diffusion expts. were done for a single compn. of the system raffinose-KCl-H2O at 25°C. Both Rayleigh and Gouy optical systems were used in all expts. for direct comparison of results from these two configurations. Various data anal. procedures are compared. Good agreement was found between the recommended results from the two optical methods, although diffusion coeffs. Dij obtained by the Rayleigh method were generally slightly lower than those obtained by the Gouy method. The sensitivity of the Dij to both exptl. error and choices of subsets of the 13 expts. is discussed. Std. errors of coeffs. are an inadequate measure of accuracy. This study has led to higher stds. for acceptability of individual expts. This system has the same mean solute concns. as the four expts. reported by P. J. Dunlop (1964), for which a test of the Onsager reciprocal relations (ORR) failed. Our diffusion results are reasonably similar to those of Dunlop. Therefore the reported failure of the ORR test probably results from errors of estg. activity coeffs. for this system rather than from diffusion data.

Analysis of Gouy Fringe Data and Comparison of Rayleigh and Gouy Optical Diffusion Measurements Using the System Raffinose (0.015 M)-KCl (0.5 M)-H2O at 25°C / D. G., Miller; Paduano, Luigi; R., Sartorio; J. G., Albright. - In: THE JOURNAL OF PHYSICAL CHEMISTRY. - ISSN 0022-3654. - STAMPA. - (1994), pp. 13745-13754.

Analysis of Gouy Fringe Data and Comparison of Rayleigh and Gouy Optical Diffusion Measurements Using the System Raffinose (0.015 M)-KCl (0.5 M)-H2O at 25°C

PADUANO, LUIGI;
1994

Abstract

Thirteen isothermal ternary diffusion expts. were done for a single compn. of the system raffinose-KCl-H2O at 25°C. Both Rayleigh and Gouy optical systems were used in all expts. for direct comparison of results from these two configurations. Various data anal. procedures are compared. Good agreement was found between the recommended results from the two optical methods, although diffusion coeffs. Dij obtained by the Rayleigh method were generally slightly lower than those obtained by the Gouy method. The sensitivity of the Dij to both exptl. error and choices of subsets of the 13 expts. is discussed. Std. errors of coeffs. are an inadequate measure of accuracy. This study has led to higher stds. for acceptability of individual expts. This system has the same mean solute concns. as the four expts. reported by P. J. Dunlop (1964), for which a test of the Onsager reciprocal relations (ORR) failed. Our diffusion results are reasonably similar to those of Dunlop. Therefore the reported failure of the ORR test probably results from errors of estg. activity coeffs. for this system rather than from diffusion data.
1994
Analysis of Gouy Fringe Data and Comparison of Rayleigh and Gouy Optical Diffusion Measurements Using the System Raffinose (0.015 M)-KCl (0.5 M)-H2O at 25°C / D. G., Miller; Paduano, Luigi; R., Sartorio; J. G., Albright. - In: THE JOURNAL OF PHYSICAL CHEMISTRY. - ISSN 0022-3654. - STAMPA. - (1994), pp. 13745-13754.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/457959
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 18
social impact