Purpose: To evaluate the accuracy of four channel multidetector row CT angiography (MDCTA) of the abdominal aorta and lower extremities arteries compared with digital subtraction angiography (DSA). Materials and methods: In our prospective study 42 patients with peripheral vascular occlusive disease (27 M. 15 F, age range 40-79 years) underwent MDCTA and DSA within 5 days. Images were blindly interpreted by two radiologists. Maximum intensity projections (MIP), multiplanar (MPR) reformations, three-dimensional (3D) reconstructions as well as axial images were available for analysis of MDCTA. DSA were analyzed on hard copies. Results: Overall sensitivity and specificity of MDCTA were 93 and 95%. respectively, with positive and negative predictive values of 90 and 97%. Overall diagnostic accuracy was 94%. Normal arterial segments and 100% occlusions were correctly identified in all cases by MDCTA. Moderately stenotic segments interpretation in the calves appeared to be more controversial, but no statistical difference in accuracy of MDCTA in the infrapopliteal district arteries was noted with respect to accuracy in the more proximal arterial bed. Good to excellent interobserver and intraobserver agreement were observed, with k values greater than 0.80. Conclusions: MDCTA of the abdominal aorta and lower extremities is an accurate imaging modality in clinical practice when compared with DSA. (C) 2003 Elsevier Ireland Ltd. All rights reserved.

Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: diagnostic accuracy and interobserver agreement / M., Romano; Mainenti, PIER PAOLO; Imbriaco, Massimo; Amato, Bruno; K., Markabaoui; O., Tamburrini; Salvatore, Marco. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - STAMPA. - 50:(2004), pp. 303-308. [10.1016/S0720-048X(03)00118-9]

Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: diagnostic accuracy and interobserver agreement

MAINENTI, PIER PAOLO;IMBRIACO, MASSIMO;AMATO, BRUNO;SALVATORE, MARCO
2004

Abstract

Purpose: To evaluate the accuracy of four channel multidetector row CT angiography (MDCTA) of the abdominal aorta and lower extremities arteries compared with digital subtraction angiography (DSA). Materials and methods: In our prospective study 42 patients with peripheral vascular occlusive disease (27 M. 15 F, age range 40-79 years) underwent MDCTA and DSA within 5 days. Images were blindly interpreted by two radiologists. Maximum intensity projections (MIP), multiplanar (MPR) reformations, three-dimensional (3D) reconstructions as well as axial images were available for analysis of MDCTA. DSA were analyzed on hard copies. Results: Overall sensitivity and specificity of MDCTA were 93 and 95%. respectively, with positive and negative predictive values of 90 and 97%. Overall diagnostic accuracy was 94%. Normal arterial segments and 100% occlusions were correctly identified in all cases by MDCTA. Moderately stenotic segments interpretation in the calves appeared to be more controversial, but no statistical difference in accuracy of MDCTA in the infrapopliteal district arteries was noted with respect to accuracy in the more proximal arterial bed. Good to excellent interobserver and intraobserver agreement were observed, with k values greater than 0.80. Conclusions: MDCTA of the abdominal aorta and lower extremities is an accurate imaging modality in clinical practice when compared with DSA. (C) 2003 Elsevier Ireland Ltd. All rights reserved.
2004
Multidetector row CT angiography of the abdominal aorta and lower extremities in patients with peripheral arterial occlusive disease: diagnostic accuracy and interobserver agreement / M., Romano; Mainenti, PIER PAOLO; Imbriaco, Massimo; Amato, Bruno; K., Markabaoui; O., Tamburrini; Salvatore, Marco. - In: EUROPEAN JOURNAL OF RADIOLOGY. - ISSN 0720-048X. - STAMPA. - 50:(2004), pp. 303-308. [10.1016/S0720-048X(03)00118-9]
File in questo prodotto:
File Dimensione Formato  
Multidetector row ct.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 160.7 kB
Formato Adobe PDF
160.7 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/442270
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 66
social impact