BACKGROUND: This study assessed the reproducibility and accuracy of 2-deoxy-2[(18)F]fluoro-D: -glucose ((18)F-FDG) for non-invasive quantification of myocardial infarct size in mice by a high-resolution positron emission tomography (PET)/computed tomography (CT) system. METHODS AND RESULTS: Mice were studied by (18)F-FDG PET/CT 1 week after induction of myocardial infarction by permanent coronary occlusion or sham procedure. In a subset of mice, PET/CT was repeated 2 days apart to assess the reproducibility of infarct size measurements. Histological analysis was used as reference method to validate imaging data. The average difference in infarct size measurements between the first and the second study was -0.42% ± 2.07% (95% confidence interval -2.6 to 1.75) with a repeatability coefficient of 4.05%. At Bland-Altman analysis, the lower and upper limits of agreement between the two repeated studies were -4.46% and 3.63%, respectively, and no correlation between difference and mean was found (P = .89). The concordance correlation coefficient was 0.99 (P < .001) and the intraclass coefficient of correlation was 0.99. A high correlation between PET/CT and histology was found for measurement of infarct size (P < .001). Using Bland-Altman analysis, the mean difference in infarct size measurement (PET/CT minus histology) was 1.9% (95% confidence interval 0.94% to 2.86%). CONCLUSIONS: In a mice model of permanent coronary occlusion non-invasive measurement of infarct size with high-resolution (18)F-FDG, PET/CT has excellent reproducibility and accuracy. These findings support the use of this methodology in serial studies.

Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT / Greco, Adelaide; Petretta, MARIA PIERA; Larobina, M; Gargiulo, Sara; Panico, M; Nekolla, Sg; Esposito, Giovanni; Petretta, Mario; Brunetti, Arturo; Cuocolo, Alberto. - In: JOURNAL OF NUCLEAR CARDIOLOGY. - ISSN 1071-3581. - 19:3(2012), pp. 492-499. [10.1007/s12350-012-9538-5]

Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT

GRECO, ADELAIDE;PETRETTA, MARIA PIERA;GARGIULO, SARA;ESPOSITO, GIOVANNI;PETRETTA, MARIO;BRUNETTI, ARTURO;CUOCOLO, ALBERTO
2012

Abstract

BACKGROUND: This study assessed the reproducibility and accuracy of 2-deoxy-2[(18)F]fluoro-D: -glucose ((18)F-FDG) for non-invasive quantification of myocardial infarct size in mice by a high-resolution positron emission tomography (PET)/computed tomography (CT) system. METHODS AND RESULTS: Mice were studied by (18)F-FDG PET/CT 1 week after induction of myocardial infarction by permanent coronary occlusion or sham procedure. In a subset of mice, PET/CT was repeated 2 days apart to assess the reproducibility of infarct size measurements. Histological analysis was used as reference method to validate imaging data. The average difference in infarct size measurements between the first and the second study was -0.42% ± 2.07% (95% confidence interval -2.6 to 1.75) with a repeatability coefficient of 4.05%. At Bland-Altman analysis, the lower and upper limits of agreement between the two repeated studies were -4.46% and 3.63%, respectively, and no correlation between difference and mean was found (P = .89). The concordance correlation coefficient was 0.99 (P < .001) and the intraclass coefficient of correlation was 0.99. A high correlation between PET/CT and histology was found for measurement of infarct size (P < .001). Using Bland-Altman analysis, the mean difference in infarct size measurement (PET/CT minus histology) was 1.9% (95% confidence interval 0.94% to 2.86%). CONCLUSIONS: In a mice model of permanent coronary occlusion non-invasive measurement of infarct size with high-resolution (18)F-FDG, PET/CT has excellent reproducibility and accuracy. These findings support the use of this methodology in serial studies.
2012
Reproducibility and accuracy of non-invasive measurement of infarct size in mice with high-resolution PET/CT / Greco, Adelaide; Petretta, MARIA PIERA; Larobina, M; Gargiulo, Sara; Panico, M; Nekolla, Sg; Esposito, Giovanni; Petretta, Mario; Brunetti, Arturo; Cuocolo, Alberto. - In: JOURNAL OF NUCLEAR CARDIOLOGY. - ISSN 1071-3581. - 19:3(2012), pp. 492-499. [10.1007/s12350-012-9538-5]
File in questo prodotto:
File Dimensione Formato  
J Nucl Cardiol 2012.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 1.55 MB
Formato Adobe PDF
1.55 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/438989
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 15
social impact