FNA biopsy of 51 orbital masses is critically reviewed. Aspiration was performed with a 23 G needle inserted by an ophthalmologist; the smears were prepared by a cytologist. Forty-two cases (83%) were correctly diagnosed as benign or malignant either with (68%) or without (15%) correct specification of the histology. There were two false-negative and seven inadequate cases. Immunocytochemical stains were performed in five cases using the following antibodies: L26 (Pan B), UCHL1 (Pan T), kappa and lambda immunoglobulin light chains (three cases) in order to distinguish inflammatory pseudotumours from low-grade non-Hodgkin's lymphomas. In two cases we used CAM 5.2 (a monoclonal cytokeratin cocktail) and vimentin to ascertain the epithelial origin of two metastatic tumours. In five other cases cytospins were not adequately cellular for immunocytochemistry. Insufficient material and one false-negative sample were obtained from very fibrotic lesions or from posteriorly located lesions. The results are discussed and compared with other series reported in the literature. Orbital FNA biopsy may be considered a useful tool in the diagnostic approach to orbital masses in which the relatively high number of inadequate aspirations is offset by a low cost-benefit ratio.

Fine needle aspiration (FNA) biopsy of orbital masses: a critical review of 51 cases / Zeppa, P; Tranfa, Fausto; Errico, Me; Troncone, Giancarlo; Fulciniti, F; Vetrani, Antonio; Bonavolontà, G; Palombini, Lucio. - In: CYTOPATHOLOGY. - ISSN 0956-5507. - STAMPA. - 8:6(1997), pp. 366-372.

Fine needle aspiration (FNA) biopsy of orbital masses: a critical review of 51 cases

TRANFA, FAUSTO;TRONCONE, GIANCARLO;VETRANI, ANTONIO;PALOMBINI, LUCIO
1997

Abstract

FNA biopsy of 51 orbital masses is critically reviewed. Aspiration was performed with a 23 G needle inserted by an ophthalmologist; the smears were prepared by a cytologist. Forty-two cases (83%) were correctly diagnosed as benign or malignant either with (68%) or without (15%) correct specification of the histology. There were two false-negative and seven inadequate cases. Immunocytochemical stains were performed in five cases using the following antibodies: L26 (Pan B), UCHL1 (Pan T), kappa and lambda immunoglobulin light chains (three cases) in order to distinguish inflammatory pseudotumours from low-grade non-Hodgkin's lymphomas. In two cases we used CAM 5.2 (a monoclonal cytokeratin cocktail) and vimentin to ascertain the epithelial origin of two metastatic tumours. In five other cases cytospins were not adequately cellular for immunocytochemistry. Insufficient material and one false-negative sample were obtained from very fibrotic lesions or from posteriorly located lesions. The results are discussed and compared with other series reported in the literature. Orbital FNA biopsy may be considered a useful tool in the diagnostic approach to orbital masses in which the relatively high number of inadequate aspirations is offset by a low cost-benefit ratio.
1997
Fine needle aspiration (FNA) biopsy of orbital masses: a critical review of 51 cases / Zeppa, P; Tranfa, Fausto; Errico, Me; Troncone, Giancarlo; Fulciniti, F; Vetrani, Antonio; Bonavolontà, G; Palombini, Lucio. - In: CYTOPATHOLOGY. - ISSN 0956-5507. - STAMPA. - 8:6(1997), pp. 366-372.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/422405
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact