Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
We report on the design and performance of the lead-scintillating fiber calorimeter of the CHORUS experiment, which searches for nu(mu)-nu(tau) oscillations in the CERN Wide Band Neutrino beam. Two of the three sectors in which the calorimeter is divided are made of lead and plastic scintillating fibers, and they represent the first large scale application of this technique for combined electromagnetic and hadronic calorimetry. The third sector is built using the sandwich technique with lead plates and scintillator strips and acts as a tail catcher for hadronic energy flow. From tests performed at the CERN SPS and PS an energy resolution of sigma(E)/E=(32.3+/-2.4)%/root E(GeV)+(1.4+/-0.7)% was measured for pions, and sigma(E)/E=(13.8+/-0.9)%/root E(GeV)+(-0.2+/-0.4)% for electrons.
Performance of the CHORUS lead-scintillating fiber calorimeter / S., B., A., C., A. G., C., D., D., E., D., U., D., A., E., M., F., Fiorillo, G., Garufi, F., P. F., L., C., L., D., M., F., M., M. A., M., M., M., P., M., Palladino, V., G., P., S., R., et al.. - In: NUCLEAR PHYSICS. B. - ISSN 0550-3213. - ELETTRONICO. - 54b:(1997), pp. 198-203. [10.1016/S0920-5632(97)00112-6]
Performance of the CHORUS lead-scintillating fiber calorimeter
S. Buontempo;A. Capone;A. G. Cocco;D. Depedis;E. DiCapua;U. Dore;A. Ereditato;M. Ferroni;FIORILLO, GIULIANA;GARUFI, FABIO;P. F. Loverre;C. Luppi;D. Macina;F. MarchettiStasi;M. A. Mazzoni;M. Messina;P. Migliozzi;PALLADINO, VITTORIO;G. Piredda;S. Ricciardi;P. Righini;B. Saitta;R. Santacesaria;P. Strolin;P. Zucchelli
1997
Abstract
We report on the design and performance of the lead-scintillating fiber calorimeter of the CHORUS experiment, which searches for nu(mu)-nu(tau) oscillations in the CERN Wide Band Neutrino beam. Two of the three sectors in which the calorimeter is divided are made of lead and plastic scintillating fibers, and they represent the first large scale application of this technique for combined electromagnetic and hadronic calorimetry. The third sector is built using the sandwich technique with lead plates and scintillator strips and acts as a tail catcher for hadronic energy flow. From tests performed at the CERN SPS and PS an energy resolution of sigma(E)/E=(32.3+/-2.4)%/root E(GeV)+(1.4+/-0.7)% was measured for pions, and sigma(E)/E=(13.8+/-0.9)%/root E(GeV)+(-0.2+/-0.4)% for electrons.
Performance of the CHORUS lead-scintillating fiber calorimeter / S., B., A., C., A. G., C., D., D., E., D., U., D., A., E., M., F., Fiorillo, G., Garufi, F., P. F., L., C., L., D., M., F., M., M. A., M., M., M., P., M., Palladino, V., G., P., S., R., et al.. - In: NUCLEAR PHYSICS. B. - ISSN 0550-3213. - ELETTRONICO. - 54b:(1997), pp. 198-203. [10.1016/S0920-5632(97)00112-6]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/412381
Citazioni
ND
2
2
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.