We carried out a careful evaluation of the performance of the large cathode area ETL 9357FLA photomultiplier tube operating at cryogenic temperature. The measurements were focused on evaluating the parameters which mainly characterize the operating performances of the device down to 77 K and the spread of the distinctive features over 54 samples assembled in the ICARUS apparatus. The results that we obtained demonstrate that the photomultiplier is suited for light detection in such unconventional operating conditions, certifying this device for the direct measurement of scintillation light coming from noble-gas liquids in detectors dedicated to neutrino physics and dark matter research. (c) 2005 Elsevier B.V. All rights reserved.
Characterization of ETL 9357FLA photomultiplier tubes for cryogenic temperature applications / A., Ankowski; M., Antonello; P., Aprili; F., Arneodo; A., Badertscher; B., Baiboussinov; M. B., Ceolin; G., Battistoni; P., Benetti; M., Bischofberger; A. B., Di; R., Brunetti; G., Bucciarelli; A., Bueno; E., Calligarich; Carbonara, Francesco; M. C., Carmona; F., Cavanna; P., Cennini; S., Centro; A., Cesana; D. B., Cline; K., Cieslik; A. G., Cocco; Z., Dai; C. D., Vecchi; A., Dabrowska; A. D., Cicco; R., Dolfini; A., Ereditato; A., Ferella; A., Ferrari; Fiorillo, Giuliana; D., Garcia Gamez; Y., Ge; D., Gibin; A. G., Berzolari; I., Gil Botella; K., Graczyk; L., Grandi; A., Guglielmi; J., Holeczek; C., Juszczak; D., Kielczewska; J., Kisiel; T., Kozlowski; M., Laffranchi; J., Lagoda; B., Lisowski; J., Lozano; M., Markiewicz; A. M., De; C., Matthey; F., Mauri; A. J., Melgarejo; A., Menegolli; G., Meng; M., Messina; C., Montanari; S., Muraro; S., Navas Concha; J., Nowak; S., Otwinowski; O., Palamara; L., Periale; G. P., Mortari; A., Piazzoli; P., Picchi; F., Pietropaolo; W., Polchlopek; M., Prata; M. C., Prata; P., Przewlocki; A., Rappoldi; G. L., Raselli; E., Roddio; M., Rossella; A., Rubbia; C., Rubbia; P. R., Sala; R., Santorelli; D., Scannicchio; E., Segreto; Y., Seo; F., Sergiampietri; J., Sobczyk; S., Stach; J., Stepaniak; R., Sulej; M., Szeptycka; M., Szarska; A., Szelc; M., Terrani; F., Varanini; S., Ventura; C., Vignoli; H., Wang; X., Yang; A., Zalewska. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 556:(2006), pp. 146-157. [10.1016/j.nima.2005.10.108]
Characterization of ETL 9357FLA photomultiplier tubes for cryogenic temperature applications
A. Ankowski;M. Antonello;P. Aprili;F. Arneodo;A. Badertscher;B. Baiboussinov;M. B. Ceolin;G. Battistoni;P. Benetti;M. Bischofberger;A. B. di;R. Brunetti;G. Bucciarelli;A. Bueno;E. Calligarich;CARBONARA, FRANCESCO;M. C. Carmona;F. Cavanna;P. Cennini;S. Centro;A. Cesana;D. B. Cline;K. Cieslik;A. G. Cocco;Z. Dai;C. D. Vecchi;A. Dabrowska;A. D. Cicco;R. Dolfini;A. Ereditato;A. Ferella;A. Ferrari;FIORILLO, GIULIANA;D. Garcia Gamez;Y. Ge;D. Gibin;A. G. Berzolari;I. Gil Botella;K. Graczyk;L. Grandi;A. Guglielmi;J. Holeczek;C. Juszczak;D. Kielczewska;J. Kisiel;T. Kozlowski;M. Laffranchi;J. Lagoda;B. Lisowski;J. Lozano;M. Markiewicz;A. M. de;C. Matthey;F. Mauri;A. J. Melgarejo;A. Menegolli;G. Meng;M. Messina;C. Montanari;S. Muraro;S. Navas Concha;J. Nowak;S. Otwinowski;O. Palamara;L. Periale;G. P. Mortari;A. Piazzoli;P. Picchi;F. Pietropaolo;W. Polchlopek;M. Prata;M. C. Prata;P. Przewlocki;A. Rappoldi;G. L. Raselli;E. Roddio;M. Rossella;A. Rubbia;C. Rubbia;P. R. Sala;R. Santorelli;D. Scannicchio;E. Segreto;Y. Seo;F. Sergiampietri;J. Sobczyk;S. Stach;J. Stepaniak;R. Sulej;M. Szeptycka;M. Szarska;A. Szelc;M. Terrani;F. Varanini;S. Ventura;C. Vignoli;H. Wang;X. Yang;A. Zalewska
2006
Abstract
We carried out a careful evaluation of the performance of the large cathode area ETL 9357FLA photomultiplier tube operating at cryogenic temperature. The measurements were focused on evaluating the parameters which mainly characterize the operating performances of the device down to 77 K and the spread of the distinctive features over 54 samples assembled in the ICARUS apparatus. The results that we obtained demonstrate that the photomultiplier is suited for light detection in such unconventional operating conditions, certifying this device for the direct measurement of scintillation light coming from noble-gas liquids in detectors dedicated to neutrino physics and dark matter research. (c) 2005 Elsevier B.V. All rights reserved.
Characterization of ETL 9357FLA photomultiplier tubes for cryogenic temperature applications / A., Ankowski; M., Antonello; P., Aprili; F., Arneodo; A., Badertscher; B., Baiboussinov; M. B., Ceolin; G., Battistoni; P., Benetti; M., Bischofberger; A. B., Di; R., Brunetti; G., Bucciarelli; A., Bueno; E., Calligarich; Carbonara, Francesco; M. C., Carmona; F., Cavanna; P., Cennini; S., Centro; A., Cesana; D. B., Cline; K., Cieslik; A. G., Cocco; Z., Dai; C. D., Vecchi; A., Dabrowska; A. D., Cicco; R., Dolfini; A., Ereditato; A., Ferella; A., Ferrari; Fiorillo, Giuliana; D., Garcia Gamez; Y., Ge; D., Gibin; A. G., Berzolari; I., Gil Botella; K., Graczyk; L., Grandi; A., Guglielmi; J., Holeczek; C., Juszczak; D., Kielczewska; J., Kisiel; T., Kozlowski; M., Laffranchi; J., Lagoda; B., Lisowski; J., Lozano; M., Markiewicz; A. M., De; C., Matthey; F., Mauri; A. J., Melgarejo; A., Menegolli; G., Meng; M., Messina; C., Montanari; S., Muraro; S., Navas Concha; J., Nowak; S., Otwinowski; O., Palamara; L., Periale; G. P., Mortari; A., Piazzoli; P., Picchi; F., Pietropaolo; W., Polchlopek; M., Prata; M. C., Prata; P., Przewlocki; A., Rappoldi; G. L., Raselli; E., Roddio; M., Rossella; A., Rubbia; C., Rubbia; P. R., Sala; R., Santorelli; D., Scannicchio; E., Segreto; Y., Seo; F., Sergiampietri; J., Sobczyk; S., Stach; J., Stepaniak; R., Sulej; M., Szeptycka; M., Szarska; A., Szelc; M., Terrani; F., Varanini; S., Ventura; C., Vignoli; H., Wang; X., Yang; A., Zalewska. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 556:(2006), pp. 146-157. [10.1016/j.nima.2005.10.108]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/412315
Citazioni
ND
54
52
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.