Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
Important open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the Standard Model of particle interactions. Addressing these questions requires a new generation of massive particle detectors to explore the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 tons) example of a new generation of detectors able to combine the imaging capabilities of the old famous ``bubble chamber'' with the excellent energy measurement of huge electronic detectors. ICARUS T600 now operates at the Gran Sasso underground laboratory and is used to study cosmic rays, neutrino oscillations and the proton decay. The potential for doing physics of this novel telescope is presented through a few examples of neutrino interactions reconstructed with unprecedented detail. Detector design and early operation are also reported.
Underground operation of the ICARUS T600 LAr-TPC: first results / C., Rubbia; M., Antonello; P., Aprili; B., Baibussinov; M., Baldo Ceolin; L., Barzè; P., Benetti; E., Calligarich; N., Canci; Carbonara, Francesco; F., Cavanna; S., Centro; A., Cesana; K., Cieslik; D. B., Cline; A. G., Cocco; A., Dabrowska; D., Dequal; A., Dermenev; R., Dolfini; C., Farnese; A., Fava; A., Ferrari; Fiorillo, Giuliana; D., Gibin; A., Gigli Berzolari; S., Gninenko; T., Golan; A., Guglielmi; M., Haranczyk; J., Holeczek; P., Karbowniczek; M., Kirsanov; J., Kisiel; I., Kochanek; J., Lagoda; M., Lantz; S., Mania; G., Mannocchi; F., Mauri; A., Menegolli; G., Meng; C., Montanari; S., Muraro; S., Otwinowski; O., Palamara; T. J., Palczewski; L., Periale; A., Piazzoli; P., Picchi; F., Pietropaolo; P., Plonski; M., Prata; P., Przewlocki; A., Rappoldi; G. L., Raselli; M., Rossella; P., Sala; E., Scantamburlo; A., Scaramelli; E., Segreto; F., Sergiampietri; J., Sobczyk; D., Stefan; J., Stepaniak; R., Sulej; M., Szarska; M., Terrani; F., Varanini; S., Ventura; C., Vignoli; T., Wachala; H., Wang; X., Yang; A., Zalewska; K., Zaremba; J., Zmuda. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 6:(2011), pp. P07011-P07011. [10.1088/1748-0221/6/07/P07011]
Underground operation of the ICARUS T600 LAr-TPC: first results
Important open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the Standard Model of particle interactions. Addressing these questions requires a new generation of massive particle detectors to explore the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 tons) example of a new generation of detectors able to combine the imaging capabilities of the old famous ``bubble chamber'' with the excellent energy measurement of huge electronic detectors. ICARUS T600 now operates at the Gran Sasso underground laboratory and is used to study cosmic rays, neutrino oscillations and the proton decay. The potential for doing physics of this novel telescope is presented through a few examples of neutrino interactions reconstructed with unprecedented detail. Detector design and early operation are also reported.
Underground operation of the ICARUS T600 LAr-TPC: first results / C., Rubbia; M., Antonello; P., Aprili; B., Baibussinov; M., Baldo Ceolin; L., Barzè; P., Benetti; E., Calligarich; N., Canci; Carbonara, Francesco; F., Cavanna; S., Centro; A., Cesana; K., Cieslik; D. B., Cline; A. G., Cocco; A., Dabrowska; D., Dequal; A., Dermenev; R., Dolfini; C., Farnese; A., Fava; A., Ferrari; Fiorillo, Giuliana; D., Gibin; A., Gigli Berzolari; S., Gninenko; T., Golan; A., Guglielmi; M., Haranczyk; J., Holeczek; P., Karbowniczek; M., Kirsanov; J., Kisiel; I., Kochanek; J., Lagoda; M., Lantz; S., Mania; G., Mannocchi; F., Mauri; A., Menegolli; G., Meng; C., Montanari; S., Muraro; S., Otwinowski; O., Palamara; T. J., Palczewski; L., Periale; A., Piazzoli; P., Picchi; F., Pietropaolo; P., Plonski; M., Prata; P., Przewlocki; A., Rappoldi; G. L., Raselli; M., Rossella; P., Sala; E., Scantamburlo; A., Scaramelli; E., Segreto; F., Sergiampietri; J., Sobczyk; D., Stefan; J., Stepaniak; R., Sulej; M., Szarska; M., Terrani; F., Varanini; S., Ventura; C., Vignoli; T., Wachala; H., Wang; X., Yang; A., Zalewska; K., Zaremba; J., Zmuda. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 6:(2011), pp. P07011-P07011. [10.1088/1748-0221/6/07/P07011]
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/412101
Citazioni
ND
137
119
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.