BACKGROUND: Accessing intradural lesions via an extended endoscopic endonasal approach requires a relatively large bony removal over the skull base. OBJECTIVE: We describe the Sonopet ultrasonic bone curette with a new dedicated endonasal hand-piece. MATERIALS AND METHODS: We used this ancillary device in 27 nonconsecutive endonasal procedures for different skull base lesions (18 standard pituitary operations and 9 extended approaches for either meningiomas or craniopharyngiomas). RESULTS: The ultrasonic bone curette with endonasal hand-piece was easy to use and effective during the removal of the bone covering or when close to the carotid and optic prominences, as well as in preserving the integrity of the superior intercavernous sinus. In only 1 case was small tearing of the dura mater observed during the bony removal. No cases of injury to the major neurovascular structures occurred. CONCLUSION: The Sonopet ultrasonic bone curette is a useful tool during endoscopic endonasal skull base surgery.

Bone Removal With a New Ultrasonic Bone Curette During Endoscopic Endonasal Approach to the Sellar-Suprasellar Area: Technical Note / Cappabianca, Paolo; Cavallo, LUIGI MARIA; Esposito, Isabella; M., Barakat; Esposito, Felice. - In: NEUROSURGERY. - ISSN 0148-396X. - STAMPA. - 66:(2010), pp. e118-e118. [10.1227/01.NEU.0000365929.26699.02]

Bone Removal With a New Ultrasonic Bone Curette During Endoscopic Endonasal Approach to the Sellar-Suprasellar Area: Technical Note

CAPPABIANCA, PAOLO;CAVALLO, LUIGI MARIA;ESPOSITO, ISABELLA;ESPOSITO, FELICE
2010

Abstract

BACKGROUND: Accessing intradural lesions via an extended endoscopic endonasal approach requires a relatively large bony removal over the skull base. OBJECTIVE: We describe the Sonopet ultrasonic bone curette with a new dedicated endonasal hand-piece. MATERIALS AND METHODS: We used this ancillary device in 27 nonconsecutive endonasal procedures for different skull base lesions (18 standard pituitary operations and 9 extended approaches for either meningiomas or craniopharyngiomas). RESULTS: The ultrasonic bone curette with endonasal hand-piece was easy to use and effective during the removal of the bone covering or when close to the carotid and optic prominences, as well as in preserving the integrity of the superior intercavernous sinus. In only 1 case was small tearing of the dura mater observed during the bony removal. No cases of injury to the major neurovascular structures occurred. CONCLUSION: The Sonopet ultrasonic bone curette is a useful tool during endoscopic endonasal skull base surgery.
2010
Bone Removal With a New Ultrasonic Bone Curette During Endoscopic Endonasal Approach to the Sellar-Suprasellar Area: Technical Note / Cappabianca, Paolo; Cavallo, LUIGI MARIA; Esposito, Isabella; M., Barakat; Esposito, Felice. - In: NEUROSURGERY. - ISSN 0148-396X. - STAMPA. - 66:(2010), pp. e118-e118. [10.1227/01.NEU.0000365929.26699.02]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/376303
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 5
social impact