The FLOTAC techniques involve the spinning of faecal samples onto the surface of counting chambers to permit enumeration of parasitic elements (eggs, larvae, oocysts and cysts) to an accuracy of one parasitic element per gramof faeces. In the present study it is demonstrated that FLOTAC provides a rapid and very sensitive method for counting of lungwormlarvae of sheep. The optimum flotation solution for lungworm larvae is zinc sulphate and mercury II iodide (s.g. 1.45) although zinc sulphate (s.g. 1.20 or 1.35) on its own also gave good results. Samples preserved in 5% formalin gave the highest counts but fresh, frozen and samples in 10% formalin also gave higher counts than McMaster and simple flotation. Larval counts of 307 field samples gave upto 1.27xmore positivessamples than use of Baermann funnels and up to 4.18x more larvae per sample. As FLOTAC is faster than Baermannisation of samples it offers a better method of counting larvae in ruminant faecal samples.
FLOTAC: an improved method for diagnosis of lungworm infections in sheep / Rinaldi, Laura; Maurelli, MARIA PAOLA; Musella, V.; Santaniello, A.; Coles, G. C.; Cringoli, Giuseppe. - In: VETERINARY PARASITOLOGY. - ISSN 0304-4017. - STAMPA. - 169:3-4(2010), pp. 395-398.
FLOTAC: an improved method for diagnosis of lungworm infections in sheep.
RINALDI, LAURA;MAURELLI, MARIA PAOLA;Santaniello A.;CRINGOLI, GIUSEPPE
2010
Abstract
The FLOTAC techniques involve the spinning of faecal samples onto the surface of counting chambers to permit enumeration of parasitic elements (eggs, larvae, oocysts and cysts) to an accuracy of one parasitic element per gramof faeces. In the present study it is demonstrated that FLOTAC provides a rapid and very sensitive method for counting of lungwormlarvae of sheep. The optimum flotation solution for lungworm larvae is zinc sulphate and mercury II iodide (s.g. 1.45) although zinc sulphate (s.g. 1.20 or 1.35) on its own also gave good results. Samples preserved in 5% formalin gave the highest counts but fresh, frozen and samples in 10% formalin also gave higher counts than McMaster and simple flotation. Larval counts of 307 field samples gave upto 1.27xmore positivessamples than use of Baermann funnels and up to 4.18x more larvae per sample. As FLOTAC is faster than Baermannisation of samples it offers a better method of counting larvae in ruminant faecal samples.File | Dimensione | Formato | |
---|---|---|---|
lungworms2.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
Accesso privato/ristretto
Dimensione
119.37 kB
Formato
Adobe PDF
|
119.37 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.