The seismic retrofit (carried out in the period February-March 2006) of the “Our Lady of Tears Shrine” in Siracusa (Italy), made substituting the bear-ings supporting its impressive dome with sliding seismic isolators equipped with elasto-plastic dissipators, has determined a significant improving of the structural behaviour. After a brief description of the new anti-seismic devices, installed between the 22 columns of the structure and the truncated-conical dome, the raising and lowering phases are examined briefly. The seismic re-trofit is shown through the results of a numerical investigation of the Sanctuary under seismic excitation compatible with the news Italian seismic code.

Seismic isolation and modeling of a worship structure / Serino, Giorgio; Spizzuoco, Mariacristina; M. R., Marsico; S., Chandrasekaran. - STAMPA. - (2008), pp. 711-718. (Intervento presentato al convegno 4ECSC - 4th European Conference on Structural Control tenutosi a St. Petersburg (Russia) nel 8-12 September 2008).

Seismic isolation and modeling of a worship structure

SERINO, GIORGIO;SPIZZUOCO, MARIACRISTINA;
2008

Abstract

The seismic retrofit (carried out in the period February-March 2006) of the “Our Lady of Tears Shrine” in Siracusa (Italy), made substituting the bear-ings supporting its impressive dome with sliding seismic isolators equipped with elasto-plastic dissipators, has determined a significant improving of the structural behaviour. After a brief description of the new anti-seismic devices, installed between the 22 columns of the structure and the truncated-conical dome, the raising and lowering phases are examined briefly. The seismic re-trofit is shown through the results of a numerical investigation of the Sanctuary under seismic excitation compatible with the news Italian seismic code.
2008
978-5-904045-10-4
Seismic isolation and modeling of a worship structure / Serino, Giorgio; Spizzuoco, Mariacristina; M. R., Marsico; S., Chandrasekaran. - STAMPA. - (2008), pp. 711-718. (Intervento presentato al convegno 4ECSC - 4th European Conference on Structural Control tenutosi a St. Petersburg (Russia) nel 8-12 September 2008).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/351828
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact