The seismic retrofit (carried out in the period February-March 2006) of the “Our Lady of Tears Shrine” in Siracusa (Italy), made substituting the bear-ings supporting its impressive dome with sliding seismic isolators equipped with elasto-plastic dissipators, has determined a significant improving of the structural behaviour. After a brief description of the new anti-seismic devices, installed between the 22 columns of the structure and the truncated-conical dome, the raising and lowering phases are examined briefly. The seismic re-trofit is shown through the results of a numerical investigation of the Sanctuary under seismic excitation compatible with the news Italian seismic code.
Seismic isolation and modeling of a worship structure / Serino, G., Spizzuoco, M., M. R., M., S., C.. - STAMPA. - (2008), pp. 711-718. (4ECSC - 4th European Conference on Structural Control St. Petersburg (Russia) 8-12 September 2008).
Seismic isolation and modeling of a worship structure
SERINO, GIORGIO;SPIZZUOCO, MARIACRISTINA;
2008
Abstract
The seismic retrofit (carried out in the period February-March 2006) of the “Our Lady of Tears Shrine” in Siracusa (Italy), made substituting the bear-ings supporting its impressive dome with sliding seismic isolators equipped with elasto-plastic dissipators, has determined a significant improving of the structural behaviour. After a brief description of the new anti-seismic devices, installed between the 22 columns of the structure and the truncated-conical dome, the raising and lowering phases are examined briefly. The seismic re-trofit is shown through the results of a numerical investigation of the Sanctuary under seismic excitation compatible with the news Italian seismic code.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


