Shielding is the only countermeasure currently available for exposure to cosmic radiation during space travel. We compared aluminum (Al) and polymethylmethacrylate (PMMA, or lucite) shields of 20 g/cm2 thickness using 1 GeV protons accelerated at the NASA Space Radiation Laboratory. The dose rate increased after the shield, and the increase was more pronounced after the Al than the PMMA shield. No significant differences in the induction of chromosomal aberrations were observed in human lymphocytes exposed to the same dose with no shield or behind the Al and PMMA blocks. However, the biological effectiveness per incident proton was increased by the shields. Simulations using the General-Purpose Particle and Heavy-Ion Transport Code System (PHITS) show that the increase in dose is caused by target fragments, and aluminum produces more secondary protons than PMMA. Nevertheless, the spectrum of particles behind the shield is confined within the low-LET region, and the biological effectiveness is consequently similar.

Comparison of aluminium and lucite for shielding against 1 GeV protons / D., Mancusi; A., Beaucei; A., Bertucci; Gialanella, Giancarlo; Grossi, Gianfranco; Manti, Lorenzo; Pugliese, Mariagabriella; A., Rusek; Scampoli, Paola; L., Sihver; Durante, Marco. - In: ADVANCES IN SPACE RESEARCH. - ISSN 0273-1177. - STAMPA. - 40:4(2007), pp. 581-585. [10.1016/j.asr.2006.11.033]

Comparison of aluminium and lucite for shielding against 1 GeV protons

GIALANELLA, GIANCARLO;GROSSI, GIANFRANCO;MANTI, LORENZO;PUGLIESE, MARIAGABRIELLA;SCAMPOLI, PAOLA;DURANTE, MARCO
2007

Abstract

Shielding is the only countermeasure currently available for exposure to cosmic radiation during space travel. We compared aluminum (Al) and polymethylmethacrylate (PMMA, or lucite) shields of 20 g/cm2 thickness using 1 GeV protons accelerated at the NASA Space Radiation Laboratory. The dose rate increased after the shield, and the increase was more pronounced after the Al than the PMMA shield. No significant differences in the induction of chromosomal aberrations were observed in human lymphocytes exposed to the same dose with no shield or behind the Al and PMMA blocks. However, the biological effectiveness per incident proton was increased by the shields. Simulations using the General-Purpose Particle and Heavy-Ion Transport Code System (PHITS) show that the increase in dose is caused by target fragments, and aluminum produces more secondary protons than PMMA. Nevertheless, the spectrum of particles behind the shield is confined within the low-LET region, and the biological effectiveness is consequently similar.
2007
Comparison of aluminium and lucite for shielding against 1 GeV protons / D., Mancusi; A., Beaucei; A., Bertucci; Gialanella, Giancarlo; Grossi, Gianfranco; Manti, Lorenzo; Pugliese, Mariagabriella; A., Rusek; Scampoli, Paola; L., Sihver; Durante, Marco. - In: ADVANCES IN SPACE RESEARCH. - ISSN 0273-1177. - STAMPA. - 40:4(2007), pp. 581-585. [10.1016/j.asr.2006.11.033]
File in questo prodotto:
File Dimensione Formato  
Adv Space Res 40 - 2007.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 459.54 kB
Formato Adobe PDF
459.54 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/341415
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact