To develop a durability design procedure based on lifetime safety factor method, different dose-response functions based on both ISO standards and the literature are presented for the prediction of the thickness loss due to atmospheric corrosion in metal structures. Finally, serviceability and ultimate limit states are defined for the durability design against corrosion.
An integrated approach to durability design of steel structures against atmospheric corrosion / Cascini, Lucrezia; Landolfo, Raffaele; Portioli, FRANCESCO PAOLO ANTONIO. - ELETTRONICO. - 385-387:(2008), pp. 657-660. (Intervento presentato al convegno 7th Int. Conf. on Fracture and Damage Mechanics tenutosi a Seoul, Korea nel 9-11 Sept 2008) [10.4028/0-87849-369-7.657].
An integrated approach to durability design of steel structures against atmospheric corrosion
CASCINI, LUCREZIA;LANDOLFO, RAFFAELE;PORTIOLI, FRANCESCO PAOLO ANTONIO
2008
Abstract
To develop a durability design procedure based on lifetime safety factor method, different dose-response functions based on both ISO standards and the literature are presented for the prediction of the thickness loss due to atmospheric corrosion in metal structures. Finally, serviceability and ultimate limit states are defined for the durability design against corrosion.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.