Supercritical flow in a bend manhole for combined sewer systems is considered for typical relative curvature and deflection angles of 45° and 90°. The typical features of bend flow in a U-shaped channel are determined, including the surface profiles along the inner and the outer bend walls, impact flow at the manhole outlet into the downstream sewer pipe, air entrainment characteristics, and wave development in the downstream sewer. Also, typical velocity distributions along the manhole are presented, and the capacity of the conventional bend structure is determined. To increase the discharge capacity across a bend manhole, the so-called bend cover is introduced. This cover element finished in steel can be removed for maintenance and inspection purposes. It limits the wave height close to the bend outlet to 90% of the sewer diameter and allows air entrainment into the downstream sewer. The performance and capacity of bend flow may significantly be increased, and the novel element may easily be added to existing manholes.

Supercritical Flow in Bend Manhole / DEL GIUDICE, Giuseppe; Gisonni, C; Hager, W. H.. - In: JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING. - ISSN 0733-9437. - STAMPA. - 126:1, January/February(2000), pp. 48-56. [10.1061/(ASCE)0733-9437(2000)126:1(48)]

Supercritical Flow in Bend Manhole

DEL GIUDICE, GIUSEPPE;
2000

Abstract

Supercritical flow in a bend manhole for combined sewer systems is considered for typical relative curvature and deflection angles of 45° and 90°. The typical features of bend flow in a U-shaped channel are determined, including the surface profiles along the inner and the outer bend walls, impact flow at the manhole outlet into the downstream sewer pipe, air entrainment characteristics, and wave development in the downstream sewer. Also, typical velocity distributions along the manhole are presented, and the capacity of the conventional bend structure is determined. To increase the discharge capacity across a bend manhole, the so-called bend cover is introduced. This cover element finished in steel can be removed for maintenance and inspection purposes. It limits the wave height close to the bend outlet to 90% of the sewer diameter and allows air entrainment into the downstream sewer. The performance and capacity of bend flow may significantly be increased, and the novel element may easily be added to existing manholes.
2000
Supercritical Flow in Bend Manhole / DEL GIUDICE, Giuseppe; Gisonni, C; Hager, W. H.. - In: JOURNAL OF IRRIGATION AND DRAINAGE ENGINEERING. - ISSN 0733-9437. - STAMPA. - 126:1, January/February(2000), pp. 48-56. [10.1061/(ASCE)0733-9437(2000)126:1(48)]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/139114
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 20
social impact