A sensitive and reproducible HPLC assay with fluorimetric detection was used to measure the malondialdheyde (MDA) concentration in food (butter, margarine, oil, fish, and meat tissue). Samples were homogenized in water supplemented with butylated hydroxytoluene. Proteins were precipitated with ice-cold 5% trichloroacetic acid and removed by centrifugation. The supernatant was incubated in a 0.28% thiobarbituric acid (TBA) mixture from which the oxygen was depleted. Optimal incubation time and temperature, for the TBA treatment, were found to be 30 min and 90°C, respectively. The MDA-TBA adduct was fractionated by reverse phase HPLC and detected by fluorescence (lambda ex= 515 nm; lambda em = 543 nm). Elution was performed at 1 mL/min flow rate with a mixture of acetonitrile and sodium phosphate at pH 7 (15:85 v/v). The described sample preparation procedure minimizes the lipid oxidation and provides high sensitivity (0.01 pmol of MDA), reproducibility, and specificity.

Measurement of malondialdheyde levels in food by High-Performance Liquid Chromatography with fluorometric detection / P., Bergamo; E., Fedele; M., Balestrieri; Abrescia, Paolo; L., Ferrara. - In: JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY. - ISSN 0021-8561. - STAMPA. - 58:(1998), pp. 2171-2176.

Measurement of malondialdheyde levels in food by High-Performance Liquid Chromatography with fluorometric detection.

ABRESCIA, PAOLO;
1998

Abstract

A sensitive and reproducible HPLC assay with fluorimetric detection was used to measure the malondialdheyde (MDA) concentration in food (butter, margarine, oil, fish, and meat tissue). Samples were homogenized in water supplemented with butylated hydroxytoluene. Proteins were precipitated with ice-cold 5% trichloroacetic acid and removed by centrifugation. The supernatant was incubated in a 0.28% thiobarbituric acid (TBA) mixture from which the oxygen was depleted. Optimal incubation time and temperature, for the TBA treatment, were found to be 30 min and 90°C, respectively. The MDA-TBA adduct was fractionated by reverse phase HPLC and detected by fluorescence (lambda ex= 515 nm; lambda em = 543 nm). Elution was performed at 1 mL/min flow rate with a mixture of acetonitrile and sodium phosphate at pH 7 (15:85 v/v). The described sample preparation procedure minimizes the lipid oxidation and provides high sensitivity (0.01 pmol of MDA), reproducibility, and specificity.
1998
Measurement of malondialdheyde levels in food by High-Performance Liquid Chromatography with fluorometric detection / P., Bergamo; E., Fedele; M., Balestrieri; Abrescia, Paolo; L., Ferrara. - In: JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY. - ISSN 0021-8561. - STAMPA. - 58:(1998), pp. 2171-2176.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/132087
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact