Background: Echocardiography (2DE) is integral for screening and longitudinal evaluation of pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc). In the present study, we sought to establish the reliability, repeatability, and reproducibility of 2DE parameters in SSc patients with and without PAH and to define the minimal detectable difference (MDD), the smallest change detected beyond measurement error. Methods: SSc patients without known PAH and with invasively confirmed PAH on stable therapies underwent 2DE with strain at two time points. Analysis of variance (ANOVA) and coefficients of variation (CV) were calculated to assess for repeatability, reliability, and reproducibility. Intra- and inter-observer agreement were assessed using intraclass correlation. Bland-Altman analysis explored the level of agreement between evaluations. MDD was calculated using the standard error of measurement for each parameter by cohort. Results: ANOVA demonstrated few significant differences between evaluations across groups. Global right ventricular longitudinal systolic strain (GRVLSS, 9.7%) and fractional area change (FAC, 21.3%) had the largest CV, while tricuspid annular plane excursion (TAPSE), S’ wave, and right ventricular outflow track velocity time integral (RVOT VTI) were 0.87%, 3.2%, and 6.0%, respectively. Intra- and inter-observer agreement was excellent. MDD for TAPSE, FAC, S’ wave, RVOT VTI, GRVLSS, and RVSP were 0.11 cm, 0.03%, 1.27 cm/s, 0.81 cm, 1.14%, and 6.5 mmHg, respectively. Conclusions: We demonstrate minimal measurement error in clinically important 2DE-based measures in SSc patients with and without PAH. Defining the MDD in this population has important implications for PAH screening, assessment of therapeutic response, and sample size calculations for future clinical trials.

Defining minimal detectable difference in echocardiographic measures of right ventricular function in systemic sclerosis / Mukherjee, Monica; Mercurio, Valentina; Balasubramanian, Aparna; Shah, Ami A; Hsu, Steven; Simpson, Catherine E; Damico, Rachel; Kolb, Todd M; Hassoun, Paul M; Mathai, Stephen C. - In: ARTHRITIS RESEARCH & THERAPY. - ISSN 1478-6362. - 24:1(2022). [10.1186/s13075-022-02835-5]

Defining minimal detectable difference in echocardiographic measures of right ventricular function in systemic sclerosis

Mercurio, Valentina;
2022

Abstract

Background: Echocardiography (2DE) is integral for screening and longitudinal evaluation of pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc). In the present study, we sought to establish the reliability, repeatability, and reproducibility of 2DE parameters in SSc patients with and without PAH and to define the minimal detectable difference (MDD), the smallest change detected beyond measurement error. Methods: SSc patients without known PAH and with invasively confirmed PAH on stable therapies underwent 2DE with strain at two time points. Analysis of variance (ANOVA) and coefficients of variation (CV) were calculated to assess for repeatability, reliability, and reproducibility. Intra- and inter-observer agreement were assessed using intraclass correlation. Bland-Altman analysis explored the level of agreement between evaluations. MDD was calculated using the standard error of measurement for each parameter by cohort. Results: ANOVA demonstrated few significant differences between evaluations across groups. Global right ventricular longitudinal systolic strain (GRVLSS, 9.7%) and fractional area change (FAC, 21.3%) had the largest CV, while tricuspid annular plane excursion (TAPSE), S’ wave, and right ventricular outflow track velocity time integral (RVOT VTI) were 0.87%, 3.2%, and 6.0%, respectively. Intra- and inter-observer agreement was excellent. MDD for TAPSE, FAC, S’ wave, RVOT VTI, GRVLSS, and RVSP were 0.11 cm, 0.03%, 1.27 cm/s, 0.81 cm, 1.14%, and 6.5 mmHg, respectively. Conclusions: We demonstrate minimal measurement error in clinically important 2DE-based measures in SSc patients with and without PAH. Defining the MDD in this population has important implications for PAH screening, assessment of therapeutic response, and sample size calculations for future clinical trials.
2022
Defining minimal detectable difference in echocardiographic measures of right ventricular function in systemic sclerosis / Mukherjee, Monica; Mercurio, Valentina; Balasubramanian, Aparna; Shah, Ami A; Hsu, Steven; Simpson, Catherine E; Damico, Rachel; Kolb, Todd M; Hassoun, Paul M; Mathai, Stephen C. - In: ARTHRITIS RESEARCH & THERAPY. - ISSN 1478-6362. - 24:1(2022). [10.1186/s13075-022-02835-5]
File in questo prodotto:
File Dimensione Formato  
Mukherjee Mercurio Arthritis Research 2022.pdf

solo utenti autorizzati

Licenza: Non specificato
Dimensione 840 kB
Formato Adobe PDF
840 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/1016195
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? ND
social impact