This paper presents a digital denoising stage for Proton Sound Detectors, that measures the range (the penetration depth) of clinical proton beams, by sensing the Time-of-Flight (ToF) of the weak acoustic signal emitted at the end of the beam penetration path. Such acoustic signal/pulse is initially fed to a low-noise analog front-end for digitalization and then to the Acoustic Denoising Digital Signal Processing (AcousticDenDSP) stage. The digital acoustic pulse has a noise bandwidth of 1 MHz and a much narrower acoustic bandwidth, centered on different fundamental frequencies (38.5 kHz (300 kHz) for 200 MeV (65 MeV) clinical beams). Thus, the AcousticDenDSP system exhibits 50 kHz/350 kHz programmable center frequency (to manage different beam energy scenarios), performs a stopband noise rejection of 80 dB/decease (4th -order) and minimize phase distortion providing a maximum Time-of- Flight error lower than 0.09% (of proton beam range). The system has been designed in 28 nm CMOS, occupies an area of 0.225 mm2 and has been fully characterized at a behavioral/electrical level (after stimulation by a real proton-induced acoustic pulse). The clock frequency is 100 MHz and the power consumption estimated is 16.9 m W, with a static power contribution of 0.075 mW.

38.5-300 kHz-Fundamental-Frequency Tuning Range 16.9 mW-Power Digital Denoising System for Proton Sound Detectors in 28 nm CMOS / Malanchini, M.; Baschirotto, A.; Di Meo, G.; Tambaro, M.; Vallicelli, E. A.; De Matteis, M.. - (2024). ( 19th Conference on Ph.D Research in Microelectronics and Electronics, PRIME 2024 cyp 2024) [10.1109/PRIME61930.2024.10559708].

38.5-300 kHz-Fundamental-Frequency Tuning Range 16.9 mW-Power Digital Denoising System for Proton Sound Detectors in 28 nm CMOS

Di Meo G.;
2024

Abstract

This paper presents a digital denoising stage for Proton Sound Detectors, that measures the range (the penetration depth) of clinical proton beams, by sensing the Time-of-Flight (ToF) of the weak acoustic signal emitted at the end of the beam penetration path. Such acoustic signal/pulse is initially fed to a low-noise analog front-end for digitalization and then to the Acoustic Denoising Digital Signal Processing (AcousticDenDSP) stage. The digital acoustic pulse has a noise bandwidth of 1 MHz and a much narrower acoustic bandwidth, centered on different fundamental frequencies (38.5 kHz (300 kHz) for 200 MeV (65 MeV) clinical beams). Thus, the AcousticDenDSP system exhibits 50 kHz/350 kHz programmable center frequency (to manage different beam energy scenarios), performs a stopband noise rejection of 80 dB/decease (4th -order) and minimize phase distortion providing a maximum Time-of- Flight error lower than 0.09% (of proton beam range). The system has been designed in 28 nm CMOS, occupies an area of 0.225 mm2 and has been fully characterized at a behavioral/electrical level (after stimulation by a real proton-induced acoustic pulse). The clock frequency is 100 MHz and the power consumption estimated is 16.9 m W, with a static power contribution of 0.075 mW.
2024
9798350386301
38.5-300 kHz-Fundamental-Frequency Tuning Range 16.9 mW-Power Digital Denoising System for Proton Sound Detectors in 28 nm CMOS / Malanchini, M.; Baschirotto, A.; Di Meo, G.; Tambaro, M.; Vallicelli, E. A.; De Matteis, M.. - (2024). ( 19th Conference on Ph.D Research in Microelectronics and Electronics, PRIME 2024 cyp 2024) [10.1109/PRIME61930.2024.10559708].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/1005471
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact