Background: Following recent epidemiological studies, which showed tissue reactions from ionizing radiation at significantly lower doses, the 2013/59 EURATOM Directive of 5th December 2013 lowered the limit on the equivalent dose to the eye lens from 150 mSv to 20 mSv per year. Therefore, as a precautionary measure, it is considered appropriate to perform a timely dose monitoring by using specific dosimeters. Objectives: Analysis of the current state of the eye lens exposures during interventional procedures. The survey aimed at assessing the degree of information available to the exposed workers as regards lowering the dose limit in Interventional Radiology departments of some hospitals in Campania (Southern Italy). Methods: The equivalent dose was assessed, over a period of 90 days, using specific Hp dosimeters(3), placed sideways with regard to prescription eye glasses. The level of awareness of the new dose limit among operators was assessed using a questionnaire. Results: The values of the equivalent dose to the lens of the eye for the I and II Operators were found to be <150 mSv/year but for the I Operator a value of 54 mSv/year was obtained, ie higher than 20 mSv/year, that is the new limit of the equivalent dose according to 2013/59 EURATOM. The initial results of the questionnaire from 52 exposed workers, of which 46 (88%) were from exposure category A and 6 (12%) from category B, showed a low level of information (19%). Conclusions: The results highlight not only the importance of using specific devices for individual protection but also the importance of the level of training and information the exposed medical staff are given concerning the new regulations.

Evaluation of the current status of the eye lens radiation exposure in an Interventional Radiology department / Pugliese, Mariagabriella; Amatiello, Antonia; Correra, Marco; Stoia, Vincenzo; Cerciello, Vincenzo; La Verde, Giuseppe; Roca, Vincenzo; Loffredo, Filomena; Fiore, Francesco. - In: LA MEDICINA DEL LAVORO. - ISSN 0025-7818. - 109:6(2018), pp. 471-477. [10.23749/mdl.v110i6.7286]

Evaluation of the current status of the eye lens radiation exposure in an Interventional Radiology department.

Pugliese, Mariagabriella
;
CERCIELLO, VINCENZO;La Verde, Giuseppe;Roca, Vincenzo;Loffredo, Filomena;
2018

Abstract

Background: Following recent epidemiological studies, which showed tissue reactions from ionizing radiation at significantly lower doses, the 2013/59 EURATOM Directive of 5th December 2013 lowered the limit on the equivalent dose to the eye lens from 150 mSv to 20 mSv per year. Therefore, as a precautionary measure, it is considered appropriate to perform a timely dose monitoring by using specific dosimeters. Objectives: Analysis of the current state of the eye lens exposures during interventional procedures. The survey aimed at assessing the degree of information available to the exposed workers as regards lowering the dose limit in Interventional Radiology departments of some hospitals in Campania (Southern Italy). Methods: The equivalent dose was assessed, over a period of 90 days, using specific Hp dosimeters(3), placed sideways with regard to prescription eye glasses. The level of awareness of the new dose limit among operators was assessed using a questionnaire. Results: The values of the equivalent dose to the lens of the eye for the I and II Operators were found to be <150 mSv/year but for the I Operator a value of 54 mSv/year was obtained, ie higher than 20 mSv/year, that is the new limit of the equivalent dose according to 2013/59 EURATOM. The initial results of the questionnaire from 52 exposed workers, of which 46 (88%) were from exposure category A and 6 (12%) from category B, showed a low level of information (19%). Conclusions: The results highlight not only the importance of using specific devices for individual protection but also the importance of the level of training and information the exposed medical staff are given concerning the new regulations.
2018
Evaluation of the current status of the eye lens radiation exposure in an Interventional Radiology department / Pugliese, Mariagabriella; Amatiello, Antonia; Correra, Marco; Stoia, Vincenzo; Cerciello, Vincenzo; La Verde, Giuseppe; Roca, Vincenzo; Loffredo, Filomena; Fiore, Francesco. - In: LA MEDICINA DEL LAVORO. - ISSN 0025-7818. - 109:6(2018), pp. 471-477. [10.23749/mdl.v110i6.7286]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/766356
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact