The aftermath of the Mw 7.1 Central Mexico earthquake struck at 13:14 CDT on 19 September 2017 confirmed, once again, the need of introducing seismic mitigation technologies that can effectively be implemented on a wide scale to reduce the seismic risk in developing regions of the world. With this in mind, the aim of this paper is the validation of Recycled Rubber-Fiber Reinforced Bearings (RR-FRBs) as base isolation devices for low-cost houses in developing counties. Results of Response History Analyses (RHAs) of a RR-FRBs base isolated residential building are discussed in this work, together with the design, Finite Element Analyses (FEAs), manufacturing and testing of full-scale prototype bearings for the building under investigation. In addition, the seismic performance of the RR-FRBs base isolated structure is compared to the response of the same building when isolated at the base with conventional devices, namely Laminated Rubber Bearings (LRBs) and Friction Pendulum Systems (FPSs). Results of this work underline the high potential of these low-cost bearings as base isolation devices for residential buildings, confirming the possibility of achieving a significant improvement of the seismic performance of ordinary structures by using the low-cost and easy to manufacture RR-FRBs.

Recycled Rubber Fiber Reinforced Bearings (RR-FRBs)as base isolators for residential buildings in developing countries: The demonstration building of Pasir Badak, Indonesia / Calabrese, A.; Losanno, D.; Spizzuoco, M.; Strano, S.; Terzo, M.. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - 192:(2019), pp. 126-144. [10.1016/j.engstruct.2019.04.076]

Recycled Rubber Fiber Reinforced Bearings (RR-FRBs)as base isolators for residential buildings in developing countries: The demonstration building of Pasir Badak, Indonesia

Losanno D.;Spizzuoco M.;Strano S.;Terzo M.
2019

Abstract

The aftermath of the Mw 7.1 Central Mexico earthquake struck at 13:14 CDT on 19 September 2017 confirmed, once again, the need of introducing seismic mitigation technologies that can effectively be implemented on a wide scale to reduce the seismic risk in developing regions of the world. With this in mind, the aim of this paper is the validation of Recycled Rubber-Fiber Reinforced Bearings (RR-FRBs) as base isolation devices for low-cost houses in developing counties. Results of Response History Analyses (RHAs) of a RR-FRBs base isolated residential building are discussed in this work, together with the design, Finite Element Analyses (FEAs), manufacturing and testing of full-scale prototype bearings for the building under investigation. In addition, the seismic performance of the RR-FRBs base isolated structure is compared to the response of the same building when isolated at the base with conventional devices, namely Laminated Rubber Bearings (LRBs) and Friction Pendulum Systems (FPSs). Results of this work underline the high potential of these low-cost bearings as base isolation devices for residential buildings, confirming the possibility of achieving a significant improvement of the seismic performance of ordinary structures by using the low-cost and easy to manufacture RR-FRBs.
2019
Recycled Rubber Fiber Reinforced Bearings (RR-FRBs)as base isolators for residential buildings in developing countries: The demonstration building of Pasir Badak, Indonesia / Calabrese, A.; Losanno, D.; Spizzuoco, M.; Strano, S.; Terzo, M.. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - 192:(2019), pp. 126-144. [10.1016/j.engstruct.2019.04.076]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/757287
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 34
social impact