Breast computed tomography (BCT) is an emerging application of X‐ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron‐radiation phase‐contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase‐contrast BCT based on the free‐space propagation approach is under development. In this paper, full‐volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high‐resolution CdTe photon‐counting detector and the projection data are processed via a phase‐retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free‐space propagation phase‐contrast imaging provide relevant three‐dimensional insights of breast morphology at clinically acceptable doses and scan times.

Advancements towards the implementation of clinical phase-contrast breast computed tomography at Elettra / Longo, R.; Arfelli, F.; Bonazza, D.; Bottigli, U.; Brombal, L.; Contillo, A.; Cova, M. A.; Delogu, P.; Di Lillo, F.; Di Trapani, V.; Donato, S.; Dreossi, D.; Fanti, V.; Fedon, C.; Golosio, B.; Mettivier, G.; Oliva, P.; Pacile, S.; Sarno, A.; Rigon, L.; Russo, Paolo; Taibi, A.; Tonutti, M.; Zanconati, F.; Tromba, G.. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 0909-0495. - 26:Pt 4(2019), pp. 1343-1353-1353. [10.1107/S1600577519005502]

Advancements towards the implementation of clinical phase-contrast breast computed tomography at Elettra

Di Lillo F.;Mettivier G.;Sarno A.;Russo Paolo;
2019

Abstract

Breast computed tomography (BCT) is an emerging application of X‐ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron‐radiation phase‐contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase‐contrast BCT based on the free‐space propagation approach is under development. In this paper, full‐volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high‐resolution CdTe photon‐counting detector and the projection data are processed via a phase‐retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free‐space propagation phase‐contrast imaging provide relevant three‐dimensional insights of breast morphology at clinically acceptable doses and scan times.
2019
Advancements towards the implementation of clinical phase-contrast breast computed tomography at Elettra / Longo, R.; Arfelli, F.; Bonazza, D.; Bottigli, U.; Brombal, L.; Contillo, A.; Cova, M. A.; Delogu, P.; Di Lillo, F.; Di Trapani, V.; Donato, S.; Dreossi, D.; Fanti, V.; Fedon, C.; Golosio, B.; Mettivier, G.; Oliva, P.; Pacile, S.; Sarno, A.; Rigon, L.; Russo, Paolo; Taibi, A.; Tonutti, M.; Zanconati, F.; Tromba, G.. - In: JOURNAL OF SYNCHROTRON RADIATION. - ISSN 0909-0495. - 26:Pt 4(2019), pp. 1343-1353-1353. [10.1107/S1600577519005502]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/756438
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 43
social impact