Abstract Objectives The study aimed to evaluate the adequacy and feasibility of the single string bifurcation stenting technique. Background Double-stent techniques may be required for complex bifurcations. Currently applied methods all have their morphological or structural limitations with respect to wall coverage, multiple strut layers, and apposition rate. Methods Single string is a novel method in which, first, the side branch (SB) stent is deployed with a single stent cell protruding into the main branch (MB). Second, the MB stent is deployed across this protruding stent cell. The procedure is completed by final kissing balloon dilation. The single string technique was first tested in vitro (n = 20) and next applied in patients (n = 11) with complex bifurcation stenoses. Results All procedures were performed successfully, crossing a single stent cell in 100%. Procedure duration was 23.0 ± 7.9 min, and the fluoroscopy time was 9.4 ± 3.5 min. The results were evaluated by optical coherence tomography, showing fully apposed struts in 83.0 ± 9.2% in the bifurcation area. Residual area obstruction in the MB was 6.4 ± 5.6% and 25.0 ± 16.9% in the SB, as evaluated by micro computed tomography. All the human cases were performed successfully with excellent angiographic results: the residual area stenosis was 27 ± 8% and 29 ± 10% in the MB and in the SB, respectively, by 3-dimensional quantitative coronary angiography. No relevant periprocedural enzyme increase was observed. During follow-up (6 ± 4 months), no adverse clinical events (death, myocardial infarction, target vessel revascularization) were noted. Conclusions The single string technique for complex bifurcation dilation was shown to be adequate in vitro and feasible in humans, with favorable results in terms of stent overlap, malapposition rate, and low residual obstruction in both the MB and SB. © 2015 American College of Cardiology Foundation.

Single String Technique for Coronary Bifurcation Stenting: Detailed Technical Evaluation and Feasibility Analysis / Toth, Gabor; Pyxaras, Stelios; Mortier, Peter; De Vroey, Frederic; Di Gioia, Giuseppe; Adjedj, Julien; Pellicano, Mariano; Ferrara, Angela; De Schryver, Thomas; Van Hoorebeke, Luc; Verhegghe, B; Barbato, Emanuele; De Bruyne, Bernard; De Beule, Matthieu; Wijns, William. - In: JACC: CARDIOVASCULAR INTERVENTIONS. - ISSN 1936-8798. - 8:7(2015), pp. 949-959. [10.1016/j.jcin.2015.01.037]

Single String Technique for Coronary Bifurcation Stenting: Detailed Technical Evaluation and Feasibility Analysis

BARBATO, EMANUELE;
2015

Abstract

Abstract Objectives The study aimed to evaluate the adequacy and feasibility of the single string bifurcation stenting technique. Background Double-stent techniques may be required for complex bifurcations. Currently applied methods all have their morphological or structural limitations with respect to wall coverage, multiple strut layers, and apposition rate. Methods Single string is a novel method in which, first, the side branch (SB) stent is deployed with a single stent cell protruding into the main branch (MB). Second, the MB stent is deployed across this protruding stent cell. The procedure is completed by final kissing balloon dilation. The single string technique was first tested in vitro (n = 20) and next applied in patients (n = 11) with complex bifurcation stenoses. Results All procedures were performed successfully, crossing a single stent cell in 100%. Procedure duration was 23.0 ± 7.9 min, and the fluoroscopy time was 9.4 ± 3.5 min. The results were evaluated by optical coherence tomography, showing fully apposed struts in 83.0 ± 9.2% in the bifurcation area. Residual area obstruction in the MB was 6.4 ± 5.6% and 25.0 ± 16.9% in the SB, as evaluated by micro computed tomography. All the human cases were performed successfully with excellent angiographic results: the residual area stenosis was 27 ± 8% and 29 ± 10% in the MB and in the SB, respectively, by 3-dimensional quantitative coronary angiography. No relevant periprocedural enzyme increase was observed. During follow-up (6 ± 4 months), no adverse clinical events (death, myocardial infarction, target vessel revascularization) were noted. Conclusions The single string technique for complex bifurcation dilation was shown to be adequate in vitro and feasible in humans, with favorable results in terms of stent overlap, malapposition rate, and low residual obstruction in both the MB and SB. © 2015 American College of Cardiology Foundation.
2015
Single String Technique for Coronary Bifurcation Stenting: Detailed Technical Evaluation and Feasibility Analysis / Toth, Gabor; Pyxaras, Stelios; Mortier, Peter; De Vroey, Frederic; Di Gioia, Giuseppe; Adjedj, Julien; Pellicano, Mariano; Ferrara, Angela; De Schryver, Thomas; Van Hoorebeke, Luc; Verhegghe, B; Barbato, Emanuele; De Bruyne, Bernard; De Beule, Matthieu; Wijns, William. - In: JACC: CARDIOVASCULAR INTERVENTIONS. - ISSN 1936-8798. - 8:7(2015), pp. 949-959. [10.1016/j.jcin.2015.01.037]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/636835
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 15
social impact