The perspective of using live cells as lenses could open new revolutionary and intriguing scenarios in the future of biophotonics and biomedical sciences for endoscopic vision, local laser treatments via optical fibres and diagnostics. Here we show that a suspended red blood cell (RBC) behaves as an adaptive liquid-lens at microscale, thus demonstrating its imaging capability and tunable focal length. In fact, thanks to the intrinsic elastic properties, the RBC can swell up from disk volume of 90fl up to a sphere reaching 150fl, varying focal length from negative to positive values. These live optofluidic lenses can be fully controlled by triggering the liquid buffer's chemistry. Real-time accurate measurement of tunable focus capability of RBCs is reported through dynamic wavefront characterization, showing agreement with numerical modelling. Moreover, in analogy to adaptive optics testing, blood diagnosis is demonstrated by screening abnormal cells through focal-spot analysis applied to an RBC ensemble as a microlens array. © 2015 Macmillan Publishers Limited. All rights reserved.

Red blood cell as an adaptive optofluidic microlens / Miccio, L; Memmolo, P.; Merola, F.; Netti, PAOLO ANTONIO; Ferraro, P.. - In: NATURE COMMUNICATIONS. - ISSN 2041-1723. - 6:(2015), p. 6502. [10.1038/ncomms7502]

Red blood cell as an adaptive optofluidic microlens

NETTI, PAOLO ANTONIO;
2015

Abstract

The perspective of using live cells as lenses could open new revolutionary and intriguing scenarios in the future of biophotonics and biomedical sciences for endoscopic vision, local laser treatments via optical fibres and diagnostics. Here we show that a suspended red blood cell (RBC) behaves as an adaptive liquid-lens at microscale, thus demonstrating its imaging capability and tunable focal length. In fact, thanks to the intrinsic elastic properties, the RBC can swell up from disk volume of 90fl up to a sphere reaching 150fl, varying focal length from negative to positive values. These live optofluidic lenses can be fully controlled by triggering the liquid buffer's chemistry. Real-time accurate measurement of tunable focus capability of RBCs is reported through dynamic wavefront characterization, showing agreement with numerical modelling. Moreover, in analogy to adaptive optics testing, blood diagnosis is demonstrated by screening abnormal cells through focal-spot analysis applied to an RBC ensemble as a microlens array. © 2015 Macmillan Publishers Limited. All rights reserved.
2015
Red blood cell as an adaptive optofluidic microlens / Miccio, L; Memmolo, P.; Merola, F.; Netti, PAOLO ANTONIO; Ferraro, P.. - In: NATURE COMMUNICATIONS. - ISSN 2041-1723. - 6:(2015), p. 6502. [10.1038/ncomms7502]
File in questo prodotto:
File Dimensione Formato  
Miccio et al Red blood cell as an adaptive optofluidic microlens.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Accesso privato/ristretto
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/619313
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 154
  • ???jsp.display-item.citation.isi??? 133
social impact