A digital imaging system for beta and gamma autoradiography has been realized. It is a hybrid pixel detector based on a Medipix2 circuit (a single photon counting chip), developed at CERN in the framework of the Medipix2 European collaboration, as a successor of the Medipix1 chip. Medipix2 is realized in 0.25-μm CMOS technology; it has a sensitive area of 14 × 14 mm2 and a pixel pitch of 55-μm and is bump bonded to a 300-μm-thick silicon pixel detector. A test of this imaging system for digital autoradiography, with a detection threshold of about 6 keV, shows a noise in the order of 10-3 cps/mm2, a minimum detectable activity of 0.32 Bq in 14 h for 3H, and 0.012 Bq in 10 h for 14C. A preliminary spatial resolution test for 14C gives a full-width at half-maximum resolution of about 80 μm. Real-time images of 3H, 14C, 125I autoradiographic microscales are shown, and a comparison with existing experimental devices is presented.

DIGITAL AUTORADIOGRAPHY WITH A MEDIPIX2 HYBRID SILICON PIXEL DETECTOR / Montesi, MARIA CRISTINA; Russo, Paolo; Mettivier, Giovanni. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 52:(2005), pp. 46-50. [10.1109/TNS.2004.843122]

DIGITAL AUTORADIOGRAPHY WITH A MEDIPIX2 HYBRID SILICON PIXEL DETECTOR

MONTESI, MARIA CRISTINA;RUSSO, PAOLO;METTIVIER, GIOVANNI
2005

Abstract

A digital imaging system for beta and gamma autoradiography has been realized. It is a hybrid pixel detector based on a Medipix2 circuit (a single photon counting chip), developed at CERN in the framework of the Medipix2 European collaboration, as a successor of the Medipix1 chip. Medipix2 is realized in 0.25-μm CMOS technology; it has a sensitive area of 14 × 14 mm2 and a pixel pitch of 55-μm and is bump bonded to a 300-μm-thick silicon pixel detector. A test of this imaging system for digital autoradiography, with a detection threshold of about 6 keV, shows a noise in the order of 10-3 cps/mm2, a minimum detectable activity of 0.32 Bq in 14 h for 3H, and 0.012 Bq in 10 h for 14C. A preliminary spatial resolution test for 14C gives a full-width at half-maximum resolution of about 80 μm. Real-time images of 3H, 14C, 125I autoradiographic microscales are shown, and a comparison with existing experimental devices is presented.
2005
DIGITAL AUTORADIOGRAPHY WITH A MEDIPIX2 HYBRID SILICON PIXEL DETECTOR / Montesi, MARIA CRISTINA; Russo, Paolo; Mettivier, Giovanni. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 52:(2005), pp. 46-50. [10.1109/TNS.2004.843122]
File in questo prodotto:
File Dimensione Formato  
digital autoradiography with a.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 809.82 kB
Formato Adobe PDF
809.82 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/204156
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 15
social impact