The paper deals with the topic of analyses performed according to modern code provisions, in particular Eurocode 8 (EC8) rules. Elastic, non-linear static and non-linear dynamic analyses of a multi-storey r/c frame building designed according to Eurocode 2 (EC2) and EC8 provisions are carried out. The beam–column hierarchy of resistance rules are applied both according to the old (1994) and the new (2003) version of EC8: the large differences are discussed. The results of two different computer programs are compared, SAP2000 and CANNY99. A suite of 7 earthquakes (each with both the horizontal components), fully satisfying the EC8 provisions, are used as input of non-lineard ynamic analyses. The results show that the 3 methods of analyses provided by EC8 for new buildings respect a correct hierarchy in terms of safety, i.e. the simpler the analysis is the safer is the result returned: the building designed according to elastic analyses is verified by both non-linear static and dynamic analyses and displacements and total chord rotations demanded by non-linear static methodology are larger than those demanded by non-linear dynamic one.

Comparison between non linear dynamic analysis performed according to EC8 and elastic and non linear static analyses / Magliulo, Gennaro; G., Maddaloni; Cosenza, Edoardo. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - ELETTRONICO. - 29:11(2007), pp. 2893-2900. [10.1016/j.engstruct.2007.01.027]

Comparison between non linear dynamic analysis performed according to EC8 and elastic and non linear static analyses

MAGLIULO, GENNARO;COSENZA, EDOARDO
2007

Abstract

The paper deals with the topic of analyses performed according to modern code provisions, in particular Eurocode 8 (EC8) rules. Elastic, non-linear static and non-linear dynamic analyses of a multi-storey r/c frame building designed according to Eurocode 2 (EC2) and EC8 provisions are carried out. The beam–column hierarchy of resistance rules are applied both according to the old (1994) and the new (2003) version of EC8: the large differences are discussed. The results of two different computer programs are compared, SAP2000 and CANNY99. A suite of 7 earthquakes (each with both the horizontal components), fully satisfying the EC8 provisions, are used as input of non-lineard ynamic analyses. The results show that the 3 methods of analyses provided by EC8 for new buildings respect a correct hierarchy in terms of safety, i.e. the simpler the analysis is the safer is the result returned: the building designed according to elastic analyses is verified by both non-linear static and dynamic analyses and displacements and total chord rotations demanded by non-linear static methodology are larger than those demanded by non-linear dynamic one.
2007
Comparison between non linear dynamic analysis performed according to EC8 and elastic and non linear static analyses / Magliulo, Gennaro; G., Maddaloni; Cosenza, Edoardo. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - ELETTRONICO. - 29:11(2007), pp. 2893-2900. [10.1016/j.engstruct.2007.01.027]
File in questo prodotto:
File Dimensione Formato  
Magliulo - Comparison between non linear dynamic analisys performed according to EC8 and elastic and non linear static analyses.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 1.81 MB
Formato Adobe PDF
1.81 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/203656
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 30
social impact